5.7 KiB
Recover From Volume Failure by Delete and Recreate The Workload Pod
Summary
The current implementation of the remount feature doesn't work when the workload pod uses subpath. This enhancement proposed a new way to handle volume remount which is deleting the workload Pod if it is controlled by a controller (e.g. deployment, statefulset, daemonset). By doing so, Kubernetes will restart the pod, detach, attach, and remount the volume.
Related Issues
https://github.com/longhorn/longhorn/issues/1719
Motivation
Goals
Make sure that when volume attached after it is detached unexpectedly or after it is auto salvaged, the workload pod can use the volume even if the containers inside the pod use subpaths.
Solution Space
#1 Use findmnt
to detect the mount point of subpath
The command findmnt <DEV-NAME>
can be used to find all existing mount points corresponding to the device.
The example output of this command when a pod is using subpath:
root@worker-1:~# findmnt /dev/longhorn/pvc-1ce69c7e-90ce-41ce-a88e-8b968d9a8ff9
TARGET SOURCE FSTYPE OPTIONS
/var/lib/kubelet/pods/0429305b-faf1-4668-aaed-139a2cf4989c/volumes/kubernetes.io~csi/pvc-1ce69c7e-90ce-41ce-a88e-8b968d9a8ff9/mount /dev/longhorn/pvc-1ce69c7e-90ce-41ce-a88e-8b968d9a8ff9 ext4 rw,rela
/var/lib/kubelet/pods/0429305b-faf1-4668-aaed-139a2cf4989c/volume-subpaths/pvc-1ce69c7e-90ce-41ce-a88e-8b968d9a8ff9/nginx/0 /dev/longhorn/pvc-1ce69c7e-90ce-41ce-a88e-8b968d9a8ff9[/html] ext4 rw,rela
We can identify which mount point is subpath and which mount point mounts to the root of the volume's filesystem. Then, Longhorn can remount the mount point which mounts to the root of the volume's filesystem.
#2 Delete the workload pod
Instead of manually finding and remounting all mount points of the volume, we delete the pod that has a controller. The pod's controller will recreate it. After that, Kubernetes handles the reattachment and remount of the volume.
This solves the issue that remount doesn't work when the workload pod uses subpath in PVC.
Proposal
I would like to choose approach #2, Delete the workload pod
because it is cleaner.
Manually doing remount is cumbersome and leaves duplicated mount points on the host.
User Stories
Story 1
Users use subpath in PVC that is bounded to Longhorn volume. When the network goes bad, the volume becomes faulty (if there is no local replica). Longhorn auto salvages the volume when the network comes back. Then Longhorn does auto-remount but the current remount logic doesn't support subpath.
User Experience In Detail
When users deploy workload using controller such as deployment, statefulset, or daemonset, They are assured that volume gets reattached and remounted in case it is detached unexpectedly.
What about a pod without a controller? Users have to manually delete and recreate it.
API changes
There is no API change
Design
Implementation Overview
The idea is that VolumeControler
will set RemountRequestedAt
when the volume needs to remount.
The KubernetesPodController
will compare RemountRequestedAt
with the pod's podStartTime
.
If pod's startTime
< vol.Status.RemountRequestAt
, KubernetesPodController
deletes the pod.
We don't delete the pod immediately though.
Wait until timeNow
> vol.Status.RemountRequestedAt
+ delayDuration
(5s).
The delayDuration
is to make sure we don't repeatedly delete the pod too fast when vol.Status.RemountRequestedAt
is updated too quickly by VolumeController
After KubernetesPodController
deletes the pod, there is no need to pass the information back to VolumeController
because there is no need to reset the field LastRemountRequestAt
which is just an event in the past.
Test plan
-
Deploy a storage class with parameter
numberOfReplicas: 1
anddatalocality: best-effort
-
Deploy a statefulset with
replicas: 1
and using the above storageclass. Make sure the container in the pod template uses subpath, like this:volumeMounts: - name: <PVC-NAME> mountPath: /mnt subPath: html
-
Find the node where the statefulset pods are running. Let's say
pod-1
is onnode-1
, and usevol-1
. -
exec into
pod-1
, create a filetest_data.txt
inside the folder/mnt/html
-
Kill the replica instance manager pod on
node-1
. This action simulates a network disconnection (the engine process of the PVC cannot talk to the replica process on the killed replica instance manager pod). -
in a 2 minutes retry loop: Exec into the
pod-1
, runls /mnt/html
. Verify the filetest_data.txt
exists. -
Kill the replica instance manager pod on
node-1
one more time. -
Wait for volume to become healthy, kill the replica instance manager pod on
node-1
one more time. -
in a 2 minutes retry loop: Exec into the
pod-1
, runls /mnt/html
. Verify the filetest_data.txt
exists. -
Update
numberOfReplicas
to 3. Wait for replicas rebuilding finishes. -
Kill the engine instance manager pod on
node-1
-
In a 2 minutes retry loop: Exec into the
pod-1
, runls /mnt/html
. Verify the filetest_data.txt
exists. -
Delete
pod-1
. -
in a 2 minutes retry loop: Exec into the
pod-1
, runls /mnt/html
. Verify the filetest_data.txt
exists.
Upgrade strategy