Change-Id: Ia1a458a0ac1c5a17d2955a3f31c6dfe77538eb17 Signed-off-by: Gregory Shapiro <gregory.shapiro@kaminario.com> Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/438562 Reviewed-by: Jim Harris <james.r.harris@intel.com> Reviewed-by: Ziye Yang <ziye.yang@intel.com> Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com> Reviewed-by: Ben Walker <benjamin.walker@intel.com> Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
103 lines
2.9 KiB
Bash
Executable File
103 lines
2.9 KiB
Bash
Executable File
#!/usr/bin/env bash
|
|
|
|
testdir=$(readlink -f $(dirname $0))
|
|
rootdir=$(readlink -f $testdir/../../..)
|
|
source $rootdir/test/common/autotest_common.sh
|
|
source $rootdir/test/nvmf/common.sh
|
|
|
|
if [ -z "${DEPENDENCY_DIR}" ]; then
|
|
echo DEPENDENCY_DIR not defined!
|
|
exit 1
|
|
fi
|
|
|
|
spdk_nvme_cli="${DEPENDENCY_DIR}/nvme-cli"
|
|
|
|
MALLOC_BDEV_SIZE=64
|
|
MALLOC_BLOCK_SIZE=512
|
|
|
|
rpc_py="$rootdir/scripts/rpc.py"
|
|
|
|
set -e
|
|
|
|
# pass the parameter 'iso' to this script when running it in isolation to trigger rdma device initialization.
|
|
# e.g. sudo ./nvme_cli.sh iso
|
|
nvmftestinit $1
|
|
|
|
RDMA_IP_LIST=$(get_available_rdma_ips)
|
|
NVMF_FIRST_TARGET_IP=$(echo "$RDMA_IP_LIST" | head -n 1)
|
|
if [ -z $NVMF_FIRST_TARGET_IP ]; then
|
|
echo "no NIC for nvmf test"
|
|
exit 0
|
|
fi
|
|
|
|
timing_enter nvme_cli
|
|
timing_enter start_nvmf_tgt
|
|
$NVMF_APP -m 0xF &
|
|
nvmfpid=$!
|
|
|
|
trap "process_shm --id $NVMF_APP_SHM_ID; killprocess $nvmfpid; nvmftestfini $1; exit 1" SIGINT SIGTERM EXIT
|
|
|
|
waitforlisten $nvmfpid
|
|
$rpc_py nvmf_create_transport -t RDMA -u 8192 -p 4
|
|
timing_exit start_nvmf_tgt
|
|
|
|
bdevs="$($rpc_py construct_malloc_bdev $MALLOC_BDEV_SIZE $MALLOC_BLOCK_SIZE) "
|
|
bdevs+="$($rpc_py construct_malloc_bdev $MALLOC_BDEV_SIZE $MALLOC_BLOCK_SIZE)"
|
|
|
|
modprobe -v nvme-rdma
|
|
|
|
$rpc_py nvmf_subsystem_create nqn.2016-06.io.spdk:cnode1 -a -s SPDK00000000000001 -d SPDK_Controller1
|
|
for bdev in $bdevs; do
|
|
$rpc_py nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode1 $bdev
|
|
done
|
|
$rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode1 -t rdma -a $NVMF_FIRST_TARGET_IP -s $NVMF_PORT
|
|
|
|
nvme connect -t rdma -n "nqn.2016-06.io.spdk:cnode1" -a "$NVMF_FIRST_TARGET_IP" -s "$NVMF_PORT"
|
|
|
|
waitforblk "nvme0n1"
|
|
waitforblk "nvme0n2"
|
|
|
|
nvme list
|
|
|
|
for ctrl in /dev/nvme?; do
|
|
nvme id-ctrl $ctrl
|
|
nvme smart-log $ctrl
|
|
nvme_model = $(nvme id-ctrl $ctrl | grep -w mn | sed 's/^.*: //')
|
|
if [ "$nvme_model" != "SPDK_Controller1" ]; then
|
|
echo "Wrong model number for controller" $nvme_model
|
|
exit 1
|
|
fi
|
|
done
|
|
|
|
for ns in /dev/nvme?n*; do
|
|
nvme id-ns $ns
|
|
done
|
|
|
|
nvme disconnect -n "nqn.2016-06.io.spdk:cnode1" || true
|
|
nvme disconnect -n "nqn.2016-06.io.spdk:cnode2" || true
|
|
|
|
if [ -d $spdk_nvme_cli ]; then
|
|
# Test spdk/nvme-cli NVMe-oF commands: discover, connect and disconnect
|
|
cd $spdk_nvme_cli
|
|
sed -i 's/shm_id=.*/shm_id=-1/g' spdk.conf
|
|
./nvme discover -t rdma -a $NVMF_FIRST_TARGET_IP -s "$NVMF_PORT"
|
|
nvme_num_before_connection=$(nvme list |grep "/dev/nvme*"|awk '{print $1}'|wc -l)
|
|
./nvme connect -t rdma -n "nqn.2016-06.io.spdk:cnode1" -a "$NVMF_FIRST_TARGET_IP" -s "$NVMF_PORT"
|
|
sleep 1
|
|
nvme_num=$(nvme list |grep "/dev/nvme*"|awk '{print $1}'|wc -l)
|
|
./nvme disconnect -n "nqn.2016-06.io.spdk:cnode1"
|
|
if [ $nvme_num -le $nvme_num_before_connection ]; then
|
|
echo "spdk/nvme-cli connect target devices failed"
|
|
exit 1
|
|
fi
|
|
fi
|
|
|
|
$rpc_py delete_nvmf_subsystem nqn.2016-06.io.spdk:cnode1
|
|
trap - SIGINT SIGTERM EXIT
|
|
|
|
nvmfcleanup
|
|
killprocess $nvmfpid
|
|
nvmftestfini $1
|
|
report_test_completion "nvmf_spdk_nvme_cli"
|
|
timing_exit nvme_cli
|