Spdk/test/nvmf/host/aer.sh
Pawel Wodkowski b96f97cf29 scripts: use python3 in all scripts
This it to prepare for RPM package. Also lower number of dependencies
needed by SPDK tools.

Update changelog to deprecate Python 2 and explicit interpeter invoking
in scripts.

Change-Id: I2497cca721cbcbadc1c99c675f8b8b7f682d5efa
Signed-off-by: Pawel Wodkowski <pawelx.wodkowski@intel.com>
Reviewed-on: https://review.gerrithub.io/425233
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Chandler-Test-Pool: SPDK Automated Test System <sys_sgsw@intel.com>
Reviewed-by: Karol Latecki <karol.latecki@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
2018-09-14 22:24:30 +00:00

77 lines
2.0 KiB
Bash
Executable File

#!/usr/bin/env bash
testdir=$(readlink -f $(dirname $0))
rootdir=$(readlink -f $testdir/../../..)
source $rootdir/test/common/autotest_common.sh
source $rootdir/test/nvmf/common.sh
rpc_py="$rootdir/scripts/rpc.py"
set -e
RDMA_IP_LIST=$(get_available_rdma_ips)
NVMF_FIRST_TARGET_IP=$(echo "$RDMA_IP_LIST" | head -n 1)
if [ -z $NVMF_FIRST_TARGET_IP ]; then
echo "no NIC for nvmf test"
exit 0
fi
timing_enter aer
timing_enter start_nvmf_tgt
$NVMF_APP -m 0xF --wait-for-rpc &
nvmfpid=$!
trap "process_shm --id $NVMF_APP_SHM_ID; killprocess $nvmfpid; exit 1" SIGINT SIGTERM EXIT
waitforlisten $nvmfpid
$rpc_py set_nvmf_target_options -u 8192 -p 4
$rpc_py start_subsystem_init
timing_exit start_nvmf_tgt
modprobe -v nvme-rdma
$rpc_py construct_malloc_bdev 64 512 --name Malloc0
$rpc_py construct_nvmf_subsystem nqn.2016-06.io.spdk:cnode1 "trtype:RDMA traddr:$NVMF_FIRST_TARGET_IP trsvcid:$NVMF_PORT" '' -a -s SPDK00000000000001 -n Malloc0 -m 2
$rpc_py get_nvmf_subsystems
# TODO: this aer test tries to invoke an AER completion by setting the temperature
#threshold to a very low value. This does not work with emulated controllers
#though so currently the test is disabled.
#$rootdir/test/nvme/aer/aer -r "\
# trtype:RDMA \
# adrfam:IPv4 \
# traddr:$NVMF_FIRST_TARGET_IP \
# trsvcid:$NVMF_PORT \
# subnqn:nqn.2014-08.org.nvmexpress.discovery"
# Namespace Attribute Notice Tests
$rootdir/test/nvme/aer/aer -r "\
trtype:RDMA \
adrfam:IPv4 \
traddr:$NVMF_FIRST_TARGET_IP \
trsvcid:$NVMF_PORT \
subnqn:nqn.2016-06.io.spdk:cnode1" -n 2 &
aerpid=$!
# Waiting for aer start to work
sleep 5
# Add a new namespace
$rpc_py construct_malloc_bdev 64 4096 --name Malloc1
$rpc_py nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode1 Malloc1 -n 2
$rpc_py get_nvmf_subsystems
wait $aerpid
$rpc_py delete_malloc_bdev Malloc0
$rpc_py delete_malloc_bdev Malloc1
$rpc_py delete_nvmf_subsystem nqn.2016-06.io.spdk:cnode1
trap - SIGINT SIGTERM EXIT
nvmfcleanup
killprocess $nvmfpid
timing_exit aer