Spdk/scripts/ceph/start.sh
paul luse eb53c23236 add (c) and SPDX header to bash files as needed
per Intel policy to include file commit date using git cmd
below.  The policy does not apply to non-Intel (C) notices.

git log --follow -C90% --format=%ad --date default <file> | tail -1

and then pull just the year from the result.

Intel copyrights were not added to files where Intel either had
no contribution ot the contribution lacked substance (ie license
header updates, formatting changes, etc)

For intel copyrights added, --follow and -C95% were used.

Signed-off-by: paul luse <paul.e.luse@intel.com>
Change-Id: I2ef86976095b88a9bf5b1003e59f3943cd6bbe4c
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/15209
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Mellanox Build Bot
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Krzysztof Karas <krzysztof.karas@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
2022-11-29 08:27:51 +00:00

145 lines
3.9 KiB
Bash
Executable File

#!/usr/bin/env bash
# SPDX-License-Identifier: BSD-3-Clause
# Copyright (C) 2017 Intel Corporation
# All rights reserved.
#
# create mon
set -x
set -e
script_dir=$(readlink -f $(dirname $0))
base_dir=/var/tmp/ceph
mon_ip=$1
mon_dir=${base_dir}/mon.a
pid_dir=${base_dir}/pid
ceph_conf=${base_dir}/ceph.conf
mnt_dir=${base_dir}/mnt
image=/var/tmp/ceph_raw.img
dev=/dev/loop200
modprobe loop
umount ${dev}p2 || true
losetup -d $dev || true
# partition osd
if [ -d $base_dir ]; then
rm -rf $base_dir
fi
mkdir ${base_dir}
cp ${script_dir}/ceph.conf $ceph_conf
if [ ! -e $image ]; then
fallocate -l 4G $image
fi
mknod ${dev} b 7 200 || true
losetup ${dev} ${image} || true
PARTED="parted -s"
SGDISK="sgdisk"
echo "Partitioning ${dev}"
${PARTED} ${dev} mktable gpt
sleep 2
${PARTED} ${dev} mkpart primary 0% 2GiB
${PARTED} ${dev} mkpart primary 2GiB 100%
partno=0
echo "Setting name on ${dev}"
${SGDISK} -c 1:osd-device-${partno}-journal ${dev}
${SGDISK} -c 2:osd-device-${partno}-data ${dev}
kpartx ${dev}
# later versions of ceph-12 have a lot of changes, to compatible with the new
# version of ceph-deploy.
ceph_version=$(ceph -v | awk '{print $3}')
ceph_maj=${ceph_version%%.*}
if [ $ceph_maj -gt 12 ]; then
update_config=true
rm -f /var/log/ceph/ceph-mon.a.log || true
set_min_mon_release="--set-min-mon-release 14"
ceph_osd_extra_config="--check-needs-journal --no-mon-config"
else
update_config=false
set_min_mon_release=""
ceph_osd_extra_config=""
fi
# prep osds
mnt_pt=${mnt_dir}/osd-device-0-data
mkdir -p ${mnt_pt}
mkfs.xfs -f /dev/disk/by-partlabel/osd-device-0-data
mount /dev/disk/by-partlabel/osd-device-0-data ${mnt_pt}
cat << EOL >> $ceph_conf
osd data = ${mnt_pt}
osd journal = /dev/disk/by-partlabel/osd-device-0-journal
# add mon address
[mon.a]
mon addr = ${mon_ip}:12046
EOL
# create mon
rm -rf "${mon_dir:?}/"*
mkdir -p ${mon_dir}
mkdir -p ${pid_dir}
rm -f /etc/ceph/ceph.client.admin.keyring
ceph-authtool --create-keyring --gen-key --name=mon. ${base_dir}/keyring --cap mon 'allow *'
ceph-authtool --gen-key --name=client.admin --cap mon 'allow *' --cap osd 'allow *' --cap mds 'allow *' --cap mgr 'allow *' ${base_dir}/keyring
monmaptool --create --clobber --add a ${mon_ip}:12046 --print ${base_dir}/monmap $set_min_mon_release
sh -c "ulimit -c unlimited && exec ceph-mon --mkfs -c ${ceph_conf} -i a --monmap=${base_dir}/monmap --keyring=${base_dir}/keyring --mon-data=${mon_dir}"
if [ $update_config = true ]; then
sed -i 's/mon addr = /mon addr = v2:/g' $ceph_conf
fi
cp ${base_dir}/keyring ${mon_dir}/keyring
cp $ceph_conf /etc/ceph/ceph.conf
cp ${base_dir}/keyring /etc/ceph/keyring
cp ${base_dir}/keyring /etc/ceph/ceph.client.admin.keyring
chmod a+r /etc/ceph/ceph.client.admin.keyring
ceph-run sh -c "ulimit -n 16384 && ulimit -c unlimited && exec ceph-mon -c ${ceph_conf} -i a --keyring=${base_dir}/keyring --pid-file=${base_dir}/pid/root@$(hostname).pid --mon-data=${mon_dir}" || true
# after ceph-mon creation, ceph -s should work.
if [ $update_config = true ]; then
# start to get whole log.
ceph-conf --name mon.a --show-config-value log_file
# add fsid to ceph config file.
fsid=$(ceph -s | grep id | awk '{print $2}')
sed -i 's/perf = true/perf = true\n\tfsid = '$fsid' \n/g' $ceph_conf
# unify the filesystem with the old versions.
sed -i 's/perf = true/perf = true\n\tosd objectstore = filestore\n/g' $ceph_conf
cat ${ceph_conf}
fi
# create osd
i=0
mkdir -p ${mnt_dir}
uuid=$(uuidgen)
ceph -c ${ceph_conf} osd create ${uuid} $i
ceph-osd -c ${ceph_conf} -i $i --mkfs --mkkey --osd-uuid ${uuid} ${ceph_osd_extra_config}
ceph -c ${ceph_conf} osd crush add osd.${i} 1.0 host=$(hostname) root=default
ceph -c ${ceph_conf} -i ${mnt_dir}/osd-device-${i}-data/keyring auth add osd.${i} osd "allow *" mon "allow profile osd" mgr "allow *"
# start osd
pkill -9 ceph-osd || true
sleep 2
mkdir -p ${pid_dir}
env -i TCMALLOC_MAX_TOTAL_THREAD_CACHE_BYTES=134217728 ceph-osd -c ${ceph_conf} -i 0 --pid-file=${pid_dir}/ceph-osd.0.pid