In order to connect to a zoned SPDK NVMe-oF target the ZNS specific
identify functions must be implemented and the supported ZNS opcodes
must be set accordingly.
Enable the zone management send and receive opcodes within the
`g_cmds_and_effect_log_page`. If the backing zoned bdev supports the
zone append command the `nvmf_get_cmds_and_effects_log_page` function
will respect that in the returned data structure.
Signed-off-by: Dennis Maisenbacher <dennis.maisenbacher@wdc.com>
Change-Id: Id9dd22a8696aa28177cc52e1f3587e10194de910
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/16045
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Shuhei Matsumoto <smatsumoto@nvidia.com>
Reviewed-by: Aleksey Marchuk <alexeymar@nvidia.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>