SPDK block devices can only be resized up when it is open. So there is no need to pause the associated namespace itself when resized - just pausing the subsystem is enough. Also modify the ns_hotplug_test to do null bdev resizing - this will help test this resize code path. Signed-off-by: Jim Harris <james.r.harris@intel.com> Change-Id: I3cb7b9de0892c296f2abf2280bed434d18ebe6b5 Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/6467 Community-CI: Broadcom CI Community-CI: Mellanox Build Bot Tested-by: SPDK CI Jenkins <sys_sgci@intel.com> Reviewed-by: Changpeng Liu <changpeng.liu@intel.com> Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com> Reviewed-by: <dongx.yi@intel.com> Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
45 lines
1.5 KiB
Bash
Executable File
45 lines
1.5 KiB
Bash
Executable File
#!/usr/bin/env bash
|
|
|
|
testdir=$(readlink -f $(dirname $0))
|
|
rootdir=$(readlink -f $testdir/../../..)
|
|
source $rootdir/test/common/autotest_common.sh
|
|
source $rootdir/test/nvmf/common.sh
|
|
|
|
rpc_py="$rootdir/scripts/rpc.py"
|
|
|
|
nvmftestinit
|
|
nvmfappstart -m 0xE
|
|
|
|
null_size=1000
|
|
|
|
$rpc_py nvmf_create_transport $NVMF_TRANSPORT_OPTS -u 8192
|
|
|
|
$rpc_py nvmf_create_subsystem nqn.2016-06.io.spdk:cnode1 -a -s SPDK00000000000001 -m 10
|
|
$rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode1 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_PORT
|
|
$rpc_py bdev_malloc_create 32 512 -b Malloc0
|
|
$rpc_py bdev_delay_create -b Malloc0 -d Delay0 -r 1000000 -t 1000000 -w 1000000 -n 1000000
|
|
$rpc_py nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode1 Delay0
|
|
$rpc_py bdev_null_create NULL1 $null_size 512
|
|
$rpc_py nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode1 NULL1
|
|
|
|
# Note: use -Q option to rate limit the error messages that perf will spew due to the
|
|
# namespace hotplugs
|
|
$SPDK_EXAMPLE_DIR/perf -c 0x1 -r "trtype:$TEST_TRANSPORT adrfam:IPv4 traddr:$NVMF_FIRST_TARGET_IP trsvcid:$NVMF_PORT" \
|
|
-t 30 -q 128 -w randread -o 512 -Q 1000 &
|
|
PERF_PID=$!
|
|
|
|
while kill -0 $PERF_PID; do
|
|
$rpc_py nvmf_subsystem_remove_ns nqn.2016-06.io.spdk:cnode1 1
|
|
$rpc_py nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode1 Delay0
|
|
# Also test bdev/namespace resizing here, since it has a similar
|
|
# effect on subsystem/namespace handling in the nvmf target
|
|
null_size=$((null_size + 1))
|
|
$rpc_py bdev_null_resize NULL1 $null_size
|
|
done
|
|
|
|
wait $PERF_PID
|
|
|
|
trap - SIGINT SIGTERM EXIT
|
|
|
|
nvmftestfini
|