Spdk/test/nvmf/target/multipath.sh
Josh Soref c9c7c281f8 spelling: test
Part of #2256

* achieve
* additionally
* against
* aliases
* already
* another
* arguments
* between
* capabilities
* comparison
* compatibility
* configuration
* continuing
* controlq
* cpumask
* default
* depends
* dereferenced
* discussed
* dissect
* driver
* environment
* everything
* excluded
* existing
* expectation
* failed
* fails
* following
* functions
* hugepages
* identifiers
* implicitly
* in_capsule
* increment
* initialization
* initiator
* integrity
* iteration
* latencies
* libraries
* management
* namespace
* negotiated
* negotiation
* nonexistent
* number
* occur
* occurred
* occurring
* offsetting
* operations
* outstanding
* overwhelmed
* parameter
* parameters
* partition
* preempts
* provisioned
* responded
* segment
* skipped
* struct
* subsystem
* success
* successfully
* sufficiently
* this
* threshold
* transfer
* transferred
* unchanged
* unexpected
* unregistered
* useless
* utility
* value
* variable
* workload

Change-Id: I21ca7dab4ef575b5767e50aaeabc34314ab13396
Signed-off-by: Josh Soref <jsoref@gmail.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/10409
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
2021-12-03 08:13:22 +00:00

128 lines
4.9 KiB
Bash
Executable File

#!/usr/bin/env bash
testdir=$(readlink -f $(dirname $0))
rootdir=$(readlink -f $testdir/../../..)
source $rootdir/test/common/autotest_common.sh
source $rootdir/test/nvmf/common.sh
MALLOC_BDEV_SIZE=64
MALLOC_BLOCK_SIZE=512
rpc_py="$rootdir/scripts/rpc.py"
function check_ana_state() {
local subsys_id=$1
local ctrl_id=$2
local ana_state=$3
# Very rarely a connection is lost and Linux NVMe host tries reconnecting
# after 10 seconds delay. For this case, set a sufficiently long timeout.
# Linux NVMe host usually recognizes the new ANA state within 2 seconds.
local timeout=20
while [ $(cat /sys/block/nvme"$subsys_id"c"$ctrl_id"n1/ana_state) != "$ana_state" ]; do
sleep 1
if ((timeout-- == 0)); then
echo "timeout before ANA state (nvme$subsys_id c$ctrl_id) becomes $ana_state"
return 1
fi
done
}
nvmftestinit
if [ -z $NVMF_SECOND_TARGET_IP ]; then
echo "only one NIC for nvmf test"
nvmftestfini
exit 0
fi
if [ "$TEST_TRANSPORT" != "tcp" ]; then
echo "run this test only with TCP transport for now"
nvmftestfini
exit 0
fi
nvmfappstart -m 0xF
$rpc_py nvmf_create_transport $NVMF_TRANSPORT_OPTS -u 8192
$rpc_py bdev_malloc_create $MALLOC_BDEV_SIZE $MALLOC_BLOCK_SIZE -b Malloc0
$rpc_py nvmf_create_subsystem nqn.2016-06.io.spdk:cnode1 -a -s SPDK00000000000001 -r
$rpc_py nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode1 Malloc0
$rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode1 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_PORT
$rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode1 -t $TEST_TRANSPORT -a $NVMF_SECOND_TARGET_IP -s $NVMF_PORT
nvme connect -t $TEST_TRANSPORT -n "nqn.2016-06.io.spdk:cnode1" -a "$NVMF_FIRST_TARGET_IP" -s "$NVMF_PORT" -g -G
nvme connect -t $TEST_TRANSPORT -n "nqn.2016-06.io.spdk:cnode1" -a "$NVMF_SECOND_TARGET_IP" -s "$NVMF_PORT" -g -G
waitforserial "$NVMF_SERIAL"
# We assume only a single subsystem.
subsys_id=$(nvme list-subsys | sed -n 's/nqn.2016-06.io.spdk:cnode1//p' | sed 's/[^0-9]*//g')
ctrl1_id=$(nvme list-subsys | sed -n "s/traddr=$NVMF_FIRST_TARGET_IP trsvcid=$NVMF_PORT//p" | sed 's/[^0-9]*//g')
ctrl2_id=$(nvme list-subsys | sed -n "s/traddr=$NVMF_SECOND_TARGET_IP trsvcid=$NVMF_PORT//p" | sed 's/[^0-9]*//g')
check_ana_state "$subsys_id" "$ctrl1_id" "optimized"
check_ana_state "$subsys_id" "$ctrl2_id" "optimized"
# Set IO policy to numa
echo numa > /sys/class/nvme-subsystem/nvme-subsys$subsys_id/iopolicy
$rootdir/scripts/fio-wrapper -p nvmf -i 4096 -d 128 -t randrw -r 6 -v &
fio_pid=$!
sleep 1
$rpc_py nvmf_subsystem_listener_set_ana_state nqn.2016-06.io.spdk:cnode1 -t $TEST_TRANSPORT -a "$NVMF_FIRST_TARGET_IP" -s "$NVMF_PORT" -n inaccessible
$rpc_py nvmf_subsystem_listener_set_ana_state nqn.2016-06.io.spdk:cnode1 -t $TEST_TRANSPORT -a "$NVMF_SECOND_TARGET_IP" -s "$NVMF_PORT" -n non_optimized
check_ana_state "$subsys_id" "$ctrl1_id" "inaccessible"
check_ana_state "$subsys_id" "$ctrl2_id" "non-optimized"
$rpc_py nvmf_subsystem_listener_set_ana_state nqn.2016-06.io.spdk:cnode1 -t $TEST_TRANSPORT -a "$NVMF_FIRST_TARGET_IP" -s "$NVMF_PORT" -n non_optimized
$rpc_py nvmf_subsystem_listener_set_ana_state nqn.2016-06.io.spdk:cnode1 -t $TEST_TRANSPORT -a "$NVMF_SECOND_TARGET_IP" -s "$NVMF_PORT" -n inaccessible
check_ana_state "$subsys_id" "$ctrl1_id" "non-optimized"
check_ana_state "$subsys_id" "$ctrl2_id" "inaccessible"
wait $fio_pid
$rpc_py nvmf_subsystem_listener_set_ana_state nqn.2016-06.io.spdk:cnode1 -t $TEST_TRANSPORT -a "$NVMF_FIRST_TARGET_IP" -s "$NVMF_PORT" -n optimized
$rpc_py nvmf_subsystem_listener_set_ana_state nqn.2016-06.io.spdk:cnode1 -t $TEST_TRANSPORT -a "$NVMF_SECOND_TARGET_IP" -s "$NVMF_PORT" -n optimized
check_ana_state "$subsys_id" "$ctrl1_id" "optimized"
check_ana_state "$subsys_id" "$ctrl2_id" "optimized"
# Set IO policy to round-robin
echo round-robin > /sys/class/nvme-subsystem/nvme-subsys$subsys_id/iopolicy
$rootdir/scripts/fio-wrapper -p nvmf -i 4096 -d 128 -t randrw -r 6 -v &
fio_pid=$!
sleep 1
$rpc_py nvmf_subsystem_listener_set_ana_state nqn.2016-06.io.spdk:cnode1 -t $TEST_TRANSPORT -a "$NVMF_FIRST_TARGET_IP" -s "$NVMF_PORT" -n inaccessible
$rpc_py nvmf_subsystem_listener_set_ana_state nqn.2016-06.io.spdk:cnode1 -t $TEST_TRANSPORT -a "$NVMF_SECOND_TARGET_IP" -s "$NVMF_PORT" -n non_optimized
check_ana_state "$subsys_id" "$ctrl1_id" "inaccessible"
check_ana_state "$subsys_id" "$ctrl2_id" "non-optimized"
$rpc_py nvmf_subsystem_listener_set_ana_state nqn.2016-06.io.spdk:cnode1 -t $TEST_TRANSPORT -a "$NVMF_FIRST_TARGET_IP" -s "$NVMF_PORT" -n non_optimized
$rpc_py nvmf_subsystem_listener_set_ana_state nqn.2016-06.io.spdk:cnode1 -t $TEST_TRANSPORT -a "$NVMF_SECOND_TARGET_IP" -s "$NVMF_PORT" -n inaccessible
check_ana_state "$subsys_id" "$ctrl1_id" "non-optimized"
check_ana_state "$subsys_id" "$ctrl2_id" "inaccessible"
wait $fio_pid
nvme disconnect -n "nqn.2016-06.io.spdk:cnode1" || true
$rpc_py nvmf_delete_subsystem nqn.2016-06.io.spdk:cnode1
rm -f ./local-job0-0-verify.state
rm -f ./local-job1-1-verify.state
trap - SIGINT SIGTERM EXIT
nvmftestfini