This was a parameter on the nvmf_create_transport
RPC, and was replaced with max_io_qpairs_per_ctrlr to
reduce confusion on whether this number included the
admin queue or not.
nvmf_vhost test was using this deprecated parameter.
Change it to use -m (max_io_qpairs_per_ctrlr)
instead. '-p 4' would have been evaluated as 1 admin
queue + 3 I/O queues, but it's likely the intent
was for 4 I/O queues. This is a perfect example of
why this parameter was deprecated.
For reference, this was deprecated in June 2020,
commit
|
||
---|---|---|
.. | ||
host | ||
target | ||
common.sh | ||
nvmf.sh | ||
README.md |
NVMe-oF test scripts
The test scripts in this directory hierarchy can be run in isolation by passing the --iso flag when running the test script. This will set up the RDMA NIC for testing and then tear it back down again when the test is completed.