Currently the default setting of cpumask of network portal is
different between iSCSI.conf and JSON-RPC.
When a network portal is created by iSCSI.conf, its cpumask is
set to all available CPUs by default. However when it is created
by JSON-RPC, its cpumask is set to 0 by default.
Auto test 'test/iscsi_tgt/idle_migration creates a network portal
by JSON-RPC. Hence the auto test cannot test the load balancing
function of iSCSI target.
Change-Id: I2685172cb9259b643f6d18d4660a8425dcef3f5d
Signed-off-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-on: https://review.gerrithub.io/391898
Tested-by: SPDK Automated Test System <sys_sgsw@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Daniel Verkamp <daniel.verkamp@intel.com>