Spdk/test/nvmf/target/create_transport.sh
Jim Harris 211cb4c250 test: don't call python explicitly
We use python3 now, not python.  This is important
because in next patch we will use a new 'aliases'
keyword argument in the argparse API that's only
available in Python 3.

While here, clean up some documentation that was
instructing users to call python explicitly instead
of just invoking scripts/rpc.py directly.

Signed-off-by: Jim Harris <james.r.harris@intel.com>
Change-Id: I0c11e131cd56f7c994aa8fe21b4b00ae33489fdd

Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/453460
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Pawel Kaminski <pawelx.kaminski@intel.com>
Reviewed-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com>
2019-05-08 14:22:19 +00:00

78 lines
2.0 KiB
Bash
Executable File

#!/usr/bin/env bash
testdir=$(readlink -f $(dirname $0))
rootdir=$(readlink -f $testdir/../../..)
source $rootdir/test/common/autotest_common.sh
source $rootdir/test/nvmf/common.sh
NULL_BDEV_SIZE=102400
NULL_BLOCK_SIZE=512
rpc_py="$rootdir/scripts/rpc.py"
set -e
# pass the parameter 'iso' to this script when running it in isolation to trigger rdma device initialization.
# e.g. sudo ./crt_trprt.sh iso
nvmftestinit $1
if ! hash nvme; then
echo "nvme command not found; skipping create transport test"
exit 0
fi
RDMA_IP_LIST=$(get_available_rdma_ips)
NVMF_FIRST_TARGET_IP=$(echo "$RDMA_IP_LIST" | head -n 1)
if [ -z $NVMF_FIRST_TARGET_IP ]; then
echo "no NIC for nvmf test"
exit 0
fi
timing_enter cr_trprt
timing_enter start_nvmf_tgt
# Start up the NVMf target in another process
$NVMF_APP -m 0xF &
nvmfpid=$!
trap "killprocess $nvmfpid; nvmftestfini $1; exit 1" SIGINT SIGTERM EXIT
waitforlisten $nvmfpid
# Use nvmf_create_transport call to create transport
$rpc_py nvmf_create_transport -t RDMA -u 8192 -p 4
timing_exit start_nvmf_tgt
null_bdevs="$($rpc_py construct_null_bdev Null0 $NULL_BDEV_SIZE $NULL_BLOCK_SIZE) "
null_bdevs+="$($rpc_py construct_null_bdev Null1 $NULL_BDEV_SIZE $NULL_BLOCK_SIZE)"
modprobe -v nvme-rdma
$rpc_py nvmf_subsystem_create nqn.2016-06.io.spdk:cnode1 -a -s SPDK00000000000001
for null_bdev in $null_bdevs; do
$rpc_py nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode1 $null_bdev
done
$rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode1 -t rdma -a $NVMF_FIRST_TARGET_IP -s 4420
nvme discover -t rdma -a $NVMF_FIRST_TARGET_IP -s $NVMF_PORT
echo "Perform nvmf subsystem discovery via RPC"
$rpc_py get_nvmf_subsystems
$rpc_py delete_nvmf_subsystem nqn.2016-06.io.spdk:cnode1
for null_bdev in $null_bdevs; do
$rpc_py delete_null_bdev $null_bdev
done
check_bdevs=$($rpc_py get_bdevs | jq -r '.[].name')
if [ -n "$check_bdevs" ]; then
echo $check_bdevs
exit 1
fi
trap - SIGINT SIGTERM EXIT
nvmfcleanup
killprocess $nvmfpid
nvmftestfini $1
timing_exit crt_trprt