This is a preparatory patch for specifying the transport when calling the script. Better to use "rdma" across the board instead of a mix of "rdma" and "RDMA". Signed-off-by: Jim Harris <james.r.harris@intel.com> Change-Id: If7170cff6ba2ec51e92a0423c0b24cc141054b55 Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/454685 Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com> Reviewed-by: Changpeng Liu <changpeng.liu@intel.com> Reviewed-by: Ben Walker <benjamin.walker@intel.com> Reviewed-by: Seth Howell <seth.howell5141@gmail.com> Reviewed-by: Paul Luse <paul.e.luse@intel.com> Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
51 lines
1.4 KiB
Bash
Executable File
51 lines
1.4 KiB
Bash
Executable File
#!/usr/bin/env bash
|
|
|
|
testdir=$(readlink -f $(dirname $0))
|
|
rootdir=$(readlink -f $testdir/../../..)
|
|
source $rootdir/test/common/autotest_common.sh
|
|
source $rootdir/test/nvmf/common.sh
|
|
|
|
MALLOC_BDEV_SIZE=64
|
|
MALLOC_BLOCK_SIZE=512
|
|
|
|
rpc_py="$rootdir/scripts/rpc.py"
|
|
|
|
set -e
|
|
|
|
# connect disconnect is geared towards ensuring that we are properly freeing resources after disconnecting qpairs.
|
|
timing_enter connect_disconnect
|
|
|
|
# pass the parameter 'iso' to this script when running it in isolation to trigger rdma device initialization.
|
|
# e.g. sudo ./filesystem.sh iso
|
|
nvmftestinit
|
|
nvmfappstart "-m 0xF"
|
|
|
|
$rpc_py nvmf_create_transport -t rdma -u 8192 -p 4 -c 0
|
|
|
|
bdev="$($rpc_py construct_malloc_bdev $MALLOC_BDEV_SIZE $MALLOC_BLOCK_SIZE)"
|
|
|
|
$rpc_py nvmf_subsystem_create nqn.2016-06.io.spdk:cnode1 -a -s SPDK00000000000001
|
|
$rpc_py nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode1 $bdev
|
|
$rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode1 -t rdma -a $NVMF_FIRST_TARGET_IP -s 4420
|
|
|
|
if [ $RUN_NIGHTLY -eq 1 ]; then
|
|
num_iterations=200
|
|
else
|
|
num_iterations=10
|
|
fi
|
|
|
|
set +x
|
|
for i in $(seq 1 $num_iterations); do
|
|
nvme connect -t rdma -n "nqn.2016-06.io.spdk:cnode1" -a "$NVMF_FIRST_TARGET_IP" -s "4420"
|
|
waitforblk "nvme0n1"
|
|
nvme disconnect -n "nqn.2016-06.io.spdk:cnode1"
|
|
waitforblk_disconnect "nvme0n1"
|
|
done
|
|
set -x
|
|
|
|
trap - SIGINT SIGTERM EXIT
|
|
|
|
nvmfcleanup
|
|
nvmftestfini
|
|
timing_exit connect_disconnect
|