Spdk/test/nvmf/host/perf.sh
Jim Harris a02b1481db test/nvmf: reduce duplication between target scripts
All of the checking for NVMF_FIRST_TARGET_IP, starting
the target, waiting on the target and modprobing
nvme-rdma is duplicated in every script.  So move
a lot of this either to nvmftestinit() or a new
nvmfappstart() function in common.sh.

Also just kill the nvmf target in nvmftestfini, rather
than the script to explicitly kill it.

Signed-off-by: Jim Harris <james.r.harris@intel.com>
Change-Id: I5864404610a4244473f460d48264de92687ed867

Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/454678
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Seth Howell <seth.howell5141@gmail.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
2019-05-17 12:48:19 +00:00

116 lines
3.6 KiB
Bash
Executable File

#!/usr/bin/env bash
testdir=$(readlink -f $(dirname $0))
rootdir=$(readlink -f $testdir/../../..)
source $rootdir/test/common/autotest_common.sh
source $rootdir/test/nvmf/common.sh
MALLOC_BDEV_SIZE=64
MALLOC_BLOCK_SIZE=512
rpc_py="$rootdir/scripts/rpc.py"
set -e
# pass the parameter 'iso' to this script when running it in isolation to trigger rdma device initialization.
# e.g. sudo ./perf.sh iso
nvmftestinit
RDMA_IP_LIST=$(get_available_rdma_ips)
NVMF_FIRST_TARGET_IP=$(echo "$RDMA_IP_LIST" | head -n 1)
TYPES="TCP"
if [ -z $NVMF_FIRST_TARGET_IP ]; then
echo "no RDMA NIC for nvmf test, will only test TCP/IP transport"
else
TYPES=${TYPES}" RDMA"
fi
timing_enter perf
timing_enter start_nvmf_tgt
$NVMF_APP -m 0xF &
nvmfpid=$!
trap "process_shm --id $NVMF_APP_SHM_ID; nvmftestfini; exit 1" SIGINT SIGTERM EXIT
waitforlisten $nvmfpid
$rootdir/scripts/gen_nvme.sh --json | $rpc_py load_subsystem_config
timing_exit start_nvmf_tgt
local_nvme_trid="trtype:PCIe traddr:"$($rpc_py get_subsystem_config bdev | jq -r '.[].params | select(.name=="Nvme0").traddr')
bdevs="$bdevs $($rpc_py construct_malloc_bdev $MALLOC_BDEV_SIZE $MALLOC_BLOCK_SIZE)"
if [ -n "$local_nvme_trid" ]; then
bdevs="$bdevs Nvme0n1"
fi
function test_perf()
{
TYPE=$1
NVMF_TARGET_IP=$2
$rpc_py nvmf_create_transport -t $TYPE -p 4
$rpc_py nvmf_subsystem_create nqn.2016-06.io.spdk:cnode1 -a -s SPDK00000000000001
for bdev in $bdevs; do
$rpc_py nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode1 $bdev
done
$rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode1 -t $TYPE -a $NVMF_TARGET_IP -s 4420
# Test multi-process access to local NVMe device
if [ -n "$local_nvme_trid" ]; then
$rootdir/examples/nvme/perf/perf -i $NVMF_APP_SHM_ID -q 32 -o 4096 -w randrw -M 50 -t 1 -r "$local_nvme_trid"
fi
$rootdir/examples/nvme/perf/perf -q 32 -o 4096 -w randrw -M 50 -t 1 -r "trtype:$TYPE adrfam:IPv4 traddr:$NVMF_TARGET_IP trsvcid:4420"
sync
$rpc_py delete_nvmf_subsystem nqn.2016-06.io.spdk:cnode1
if [ $RUN_NIGHTLY -eq 1 ]; then
# Configure nvme devices with nvmf lvol_bdev backend
if [ -n "$local_nvme_trid" ]; then
ls_guid=$($rpc_py construct_lvol_store Nvme0n1 lvs_0)
get_lvs_free_mb $ls_guid
lb_guid=$($rpc_py construct_lvol_bdev -u $ls_guid lbd_0 $free_mb)
# Create lvol bdev for nested lvol stores
ls_nested_guid=$($rpc_py construct_lvol_store $lb_guid lvs_n_0)
get_lvs_free_mb $ls_nested_guid
lb_nested_guid=$($rpc_py construct_lvol_bdev -u $ls_nested_guid lbd_nest_0 $free_mb)
$rpc_py nvmf_subsystem_create nqn.2016-06.io.spdk:cnode1 -a -s SPDK00000000000001
for bdev in $lb_nested_guid; do
$rpc_py nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode1 $bdev
done
$rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode1 -t $TYPE -a $NVMF_TARGET_IP -s 4420
# Test perf as host with different io_size and qd_depth in nightly
qd_depth=("1" "128")
io_size=("512" "131072")
for qd in ${qd_depth[@]}; do
for o in ${io_size[@]}; do
$rootdir/examples/nvme/perf/perf -q $qd -o $o -w randrw -M 50 -t 10 -r "trtype:$TYPE adrfam:IPv4 traddr:$NVMF_TARGET_IP trsvcid:4420"
done
done
# Delete subsystems, lvol_bdev and destroy lvol_store.
$rpc_py delete_nvmf_subsystem nqn.2016-06.io.spdk:cnode1
$rpc_py destroy_lvol_bdev "$lb_nested_guid"
$rpc_py destroy_lvol_store -l lvs_n_0
$rpc_py destroy_lvol_bdev "$lb_guid"
$rpc_py destroy_lvol_store -l lvs_0
fi
fi
}
for type in $TYPES; do
if [ $type == "TCP" ]; then
nvmf_tgt_ip=$NVMF_TCP_IP_ADDRESS
else
nvmf_tgt_ip=$NVMF_FIRST_TARGET_IP
fi
test_perf $type $nvmf_tgt_ip
done
trap - SIGINT SIGTERM EXIT
nvmftestfini
timing_exit perf