Good suggestion from Darek - let's just always parse common script args from autotest_common.sh. These arguments follow common arg naming conventions (i.e. --iso) so there's no harm just doing this for any test that sources autotest_common.sh. This has the nice effect of not requiring scripts to explicitly call this function. Signed-off-by: Jim Harris <james.r.harris@intel.com> Change-Id: Id89b68c22557a5a771be407873d0e57843f0d05a Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/455552 Tested-by: SPDK CI Jenkins <sys_sgci@intel.com> Reviewed-by: Seth Howell <seth.howell5141@gmail.com> Reviewed-by: Changpeng Liu <changpeng.liu@intel.com> Reviewed-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com>
65 lines
1.9 KiB
Bash
Executable File
65 lines
1.9 KiB
Bash
Executable File
#!/usr/bin/env bash
|
|
|
|
testdir=$(readlink -f $(dirname $0))
|
|
rootdir=$(readlink -f $testdir/../../..)
|
|
source $rootdir/test/common/autotest_common.sh
|
|
source $rootdir/test/nvmf/common.sh
|
|
|
|
MALLOC_BDEV_SIZE=64
|
|
MALLOC_BLOCK_SIZE=512
|
|
|
|
rpc_py="$rootdir/scripts/rpc.py"
|
|
|
|
set -e
|
|
|
|
timing_enter nmic
|
|
nvmftestinit
|
|
nvmfappstart "-m 0xF"
|
|
|
|
NVMF_SECOND_TARGET_IP=$(echo "$RDMA_IP_LIST" | sed -n 2p)
|
|
|
|
$rpc_py nvmf_create_transport -t rdma -u 8192
|
|
|
|
# Create subsystems
|
|
$rpc_py construct_malloc_bdev $MALLOC_BDEV_SIZE $MALLOC_BLOCK_SIZE -b Malloc0
|
|
$rpc_py nvmf_subsystem_create nqn.2016-06.io.spdk:cnode1 -a -s SPDK1
|
|
$rpc_py nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode1 Malloc0
|
|
$rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode1 -t rdma -a $NVMF_FIRST_TARGET_IP -s "$NVMF_PORT"
|
|
|
|
echo "test case1: single bdev can't be used in multiple subsystems"
|
|
set +e
|
|
$rpc_py nvmf_subsystem_create nqn.2016-06.io.spdk:cnode2 -a -s SPDK2
|
|
$rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode2 -t rdma -a $NVMF_FIRST_TARGET_IP -s "$NVMF_PORT"
|
|
$rpc_py nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode2 Malloc0
|
|
nmic_status=$?
|
|
|
|
if [ $nmic_status -eq 0 ]; then
|
|
echo " Adding namespace passed - failure expected."
|
|
nvmfcleanup
|
|
nvmftestfini
|
|
exit 1
|
|
else
|
|
echo " Adding namespace failed - expected result."
|
|
fi
|
|
set -e
|
|
|
|
echo "test case2: host connect to nvmf target in multiple paths"
|
|
if [ ! -z $NVMF_SECOND_TARGET_IP ]; then
|
|
$rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode1 -t rdma -a $NVMF_SECOND_TARGET_IP -s $NVMF_PORT
|
|
|
|
nvme connect -t rdma -n "nqn.2016-06.io.spdk:cnode1" -a "$NVMF_FIRST_TARGET_IP" -s "$NVMF_PORT"
|
|
nvme connect -t rdma -n "nqn.2016-06.io.spdk:cnode1" -a "$NVMF_SECOND_TARGET_IP" -s "$NVMF_PORT"
|
|
|
|
waitforblk "nvme0n1"
|
|
|
|
$rootdir/scripts/fio.py nvmf 4096 1 write 1 1 verify
|
|
fi
|
|
|
|
nvme disconnect -n "nqn.2016-06.io.spdk:cnode1" || true
|
|
|
|
trap - SIGINT SIGTERM EXIT
|
|
|
|
nvmfcleanup
|
|
nvmftestfini
|
|
timing_exit nmic
|