These functions enable a user to run one of the Nvme-oF tests directly from the command line without having to manually invoke all of the setup we typically do. Change-Id: Ib0baa77c08abb24c2fa2a1e21cf38ac613d663e0 Signed-off-by: Seth Howell <seth.howell@intel.com> Reviewed-on: https://review.gerrithub.io/422336 Tested-by: SPDK CI Jenkins <sys_sgci@intel.com> Reviewed-by: Ben Walker <benjamin.walker@intel.com> Reviewed-by: Jim Harris <james.r.harris@intel.com> Chandler-Test-Pool: SPDK Automated Test System <sys_sgsw@intel.com>
72 lines
1.9 KiB
Bash
Executable File
72 lines
1.9 KiB
Bash
Executable File
#!/usr/bin/env bash
|
|
|
|
testdir=$(readlink -f $(dirname $0))
|
|
rootdir=$(readlink -f $testdir/../../..)
|
|
source $rootdir/test/common/autotest_common.sh
|
|
source $rootdir/test/nvmf/common.sh
|
|
|
|
MALLOC_BDEV_SIZE=128
|
|
MALLOC_BLOCK_SIZE=512
|
|
|
|
rpc_py="python $rootdir/scripts/rpc.py"
|
|
|
|
set -e
|
|
|
|
# pass the parameter 'iso' to this script when running it in isolation to trigger rdma device initialization.
|
|
# e.g. sudo ./shutdown.sh iso
|
|
nvmftestinit $1
|
|
|
|
RDMA_IP_LIST=$(get_available_rdma_ips)
|
|
NVMF_FIRST_TARGET_IP=$(echo "$RDMA_IP_LIST" | head -n 1)
|
|
if [ -z $NVMF_FIRST_TARGET_IP ]; then
|
|
echo "no NIC for nvmf test"
|
|
exit 0
|
|
fi
|
|
|
|
timing_enter shutdown
|
|
timing_enter start_nvmf_tgt
|
|
# Start up the NVMf target in another process
|
|
$NVMF_APP -m 0xF --wait-for-rpc &
|
|
pid=$!
|
|
|
|
trap "killprocess $pid; nvmfcleanup; nvmftestfini $1; exit 1" SIGINT SIGTERM EXIT
|
|
|
|
waitforlisten $pid
|
|
$rpc_py set_nvmf_target_options -u 8192 -p 4
|
|
$rpc_py start_subsystem_init
|
|
timing_exit start_nvmf_tgt
|
|
|
|
num_subsystems=10
|
|
# SoftRoce does not have enough queues available for
|
|
# this test. Detect if we're using software RDMA.
|
|
# If so, only use one subsystem.
|
|
if check_ip_is_soft_roce "$NVMF_FIRST_TARGET_IP"; then
|
|
num_subsystems=1
|
|
fi
|
|
|
|
# Create subsystems
|
|
for i in `seq 1 $num_subsystems`
|
|
do
|
|
bdevs="$($rpc_py construct_malloc_bdev $MALLOC_BDEV_SIZE $MALLOC_BLOCK_SIZE)"
|
|
$rpc_py construct_nvmf_subsystem nqn.2016-06.io.spdk:cnode${i} "trtype:RDMA traddr:$NVMF_FIRST_TARGET_IP trsvcid:$NVMF_PORT" '' -a -s SPDK${i} -n "$bdevs"
|
|
done
|
|
|
|
modprobe -v nvme-rdma
|
|
modprobe -v nvme-fabrics
|
|
|
|
# Connect kernel host to subsystems
|
|
for i in `seq 1 $num_subsystems`; do
|
|
nvme connect -t rdma -n "nqn.2016-06.io.spdk:cnode${i}" -a "$NVMF_FIRST_TARGET_IP" -s "$NVMF_PORT"
|
|
done
|
|
|
|
# Kill nvmf tgt without removing any subsystem to check whether it can shutdown correctly
|
|
rm -f ./local-job0-0-verify.state
|
|
|
|
trap - SIGINT SIGTERM EXIT
|
|
|
|
killprocess $pid
|
|
|
|
nvmfcleanup
|
|
nvmftestfini $1
|
|
timing_exit shutdown
|