Spdk/test/nvmf/target/ns_hotplug_stress.sh
Jim Harris d98c37495a test: add explicit listener for discovery subsystem
Ensures compliance now that we've deprecated being
able to connect to any listener without adding it to
the discovery subsystem first.

This patch was tested with a temporary change that
removes the default discovery listener.  It is
possible that future test changes could again
depend on this deprecated behavior, but at least
now all existing tests will explicitly create the
discovery listener, making it more likely that
new tests will copy the correct behavior.

Signed-off-by: Jim Harris <james.r.harris@intel.com>
Change-Id: I936d3d124e22a56548ea43c73ca8197c22ec0f66
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/11541
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Reviewed-by: Shuhei Matsumoto <smatsumoto@nvidia.com>
2022-02-28 11:06:16 +00:00

46 lines
1.6 KiB
Bash
Executable File

#!/usr/bin/env bash
testdir=$(readlink -f $(dirname $0))
rootdir=$(readlink -f $testdir/../../..)
source $rootdir/test/common/autotest_common.sh
source $rootdir/test/nvmf/common.sh
rpc_py="$rootdir/scripts/rpc.py"
nvmftestinit
nvmfappstart -m 0xE
null_size=1000
$rpc_py nvmf_create_transport $NVMF_TRANSPORT_OPTS -u 8192
$rpc_py nvmf_create_subsystem nqn.2016-06.io.spdk:cnode1 -a -s SPDK00000000000001 -m 10
$rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode1 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_PORT
$rpc_py nvmf_subsystem_add_listener discovery -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_PORT
$rpc_py bdev_malloc_create 32 512 -b Malloc0
$rpc_py bdev_delay_create -b Malloc0 -d Delay0 -r 1000000 -t 1000000 -w 1000000 -n 1000000
$rpc_py nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode1 Delay0
$rpc_py bdev_null_create NULL1 $null_size 512
$rpc_py nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode1 NULL1
# Note: use -Q option to rate limit the error messages that perf will spew due to the
# namespace hotplugs
$SPDK_EXAMPLE_DIR/perf -c 0x1 -r "trtype:$TEST_TRANSPORT adrfam:IPv4 traddr:$NVMF_FIRST_TARGET_IP trsvcid:$NVMF_PORT" \
-t 30 -q 128 -w randread -o 512 -Q 1000 &
PERF_PID=$!
while kill -0 $PERF_PID; do
$rpc_py nvmf_subsystem_remove_ns nqn.2016-06.io.spdk:cnode1 1
$rpc_py nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode1 Delay0
# Also test bdev/namespace resizing here, since it has a similar
# effect on subsystem/namespace handling in the nvmf target
null_size=$((null_size + 1))
$rpc_py bdev_null_resize NULL1 $null_size
done
wait $PERF_PID
trap - SIGINT SIGTERM EXIT
nvmftestfini