Spdk/test/nvmf/target/shutdown.sh
Ben Walker 5dfd4f261f test/nvmf: Restart target between shutdown tests
For RDMA, it seems we may have to wait out some timeouts to
reset all of the connections to make this test work reliably. Instead,
just restart the target for each test.

If there's a way to force close all of the connections properly in the
future we can go back to running these all on a single target.

Change-Id: If79257349007765dc16bacebf810312a025d70a3
Signed-off-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/1609
Community-CI: Broadcom CI
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
2020-04-14 11:32:35 +00:00

162 lines
4.3 KiB
Bash
Executable File

#!/usr/bin/env bash
testdir=$(readlink -f $(dirname $0))
rootdir=$(readlink -f $testdir/../../..)
source $rootdir/test/common/autotest_common.sh
source $rootdir/test/nvmf/common.sh
MALLOC_BDEV_SIZE=64
MALLOC_BLOCK_SIZE=512
rpc_py="$rootdir/scripts/rpc.py"
function starttarget() {
# Start the target
nvmfappstart "-m 0x1E"
$rpc_py nvmf_create_transport $NVMF_TRANSPORT_OPTS -u 8192
num_subsystems=10
# SoftRoce does not have enough queues available for
# this test. Detect if we're using software RDMA.
# If so, only use two subsystem.
if check_ip_is_soft_roce "$NVMF_FIRST_TARGET_IP"; then
num_subsystems=2
fi
touch $testdir/bdevperf.conf
echo "[Nvme]" > $testdir/bdevperf.conf
timing_enter create_subsystems
# Create subsystems
rm -rf $testdir/rpcs.txt
for i in $(seq 1 $num_subsystems)
do
cat <<- EOL >> $testdir/rpcs.txt
bdev_malloc_create $MALLOC_BDEV_SIZE $MALLOC_BLOCK_SIZE -b Malloc$i
nvmf_create_subsystem nqn.2016-06.io.spdk:cnode$i -a -s SPDK$i
nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode$i Malloc$i
nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode$i -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_PORT
EOL
echo " TransportID \"trtype:$TEST_TRANSPORT adrfam:IPv4 subnqn:nqn.2016-06.io.spdk:cnode$i traddr:$NVMF_FIRST_TARGET_IP trsvcid:$NVMF_PORT hostaddr:$NVMF_FIRST_TARGET_IP\" Nvme$i" >> $testdir/bdevperf.conf
done
$rpc_py < $testdir/rpcs.txt
timing_exit create_subsystems
}
function stoptarget() {
rm -f ./local-job0-0-verify.state
rm -rf $testdir/bdevperf.conf
rm -rf $testdir/rpcs.txt
nvmftestfini
}
function waitforio() {
# $1 = RPC socket
if [ -z "$1" ]; then
exit 1
fi
# $2 = bdev name
if [ -z "$2" ]; then
exit 1
fi
local ret=1
local i
for (( i = 10; i != 0; i-- )); do
read_io_count=$($rpc_py -s $1 bdev_get_iostat -b $2 | jq -r '.bdevs[0].num_read_ops')
# A few I/O will happen during initial examine. So wait until at least 100 I/O
# have completed to know that bdevperf is really generating the I/O.
if [ $read_io_count -ge 100 ]; then
ret=0
break
fi
sleep 0.25
done
return $ret
}
# Test 1: Kill the initiator unexpectedly with no I/O outstanding
function nvmf_shutdown_tc1 {
starttarget
# Run bdev_svc, which connects but does not issue I/O
$rootdir/test/app/bdev_svc/bdev_svc -m 0x1 -i 1 -r /var/tmp/bdevperf.sock -c $testdir/bdevperf.conf &
perfpid=$!
waitforlisten $perfpid /var/tmp/bdevperf.sock
$rpc_py -s /var/tmp/bdevperf.sock framework_wait_init
# Kill bdev_svc
kill -9 $perfpid || true
rm -f /var/run/spdk_bdev1
# Verify the target stays up
sleep 1
kill -0 $nvmfpid
# Connect with bdevperf and confirm it works
$rootdir/test/bdev/bdevperf/bdevperf -r /var/tmp/bdevperf.sock -c $testdir/bdevperf.conf -q 64 -o 65536 -w verify -t 1
stoptarget
}
# Test 2: Kill initiator unexpectedly with I/O outstanding
function nvmf_shutdown_tc2 {
starttarget
# Run bdevperf
$rootdir/test/bdev/bdevperf/bdevperf -r /var/tmp/bdevperf.sock -c $testdir/bdevperf.conf -q 64 -o 65536 -w verify -t 10 &
perfpid=$!
waitforlisten $perfpid /var/tmp/bdevperf.sock
$rpc_py -s /var/tmp/bdevperf.sock framework_wait_init
waitforio /var/tmp/bdevperf.sock Nvme1n1
# Kill bdevperf half way through
killprocess $perfpid
# Verify the target stays up
sleep 1
kill -0 $nvmfpid
stoptarget
}
# Test 3: Kill the target unexpectedly with I/O outstanding
function nvmf_shutdown_tc3 {
starttarget
# Run bdevperf
$rootdir/test/bdev/bdevperf/bdevperf -r /var/tmp/bdevperf.sock -c $testdir/bdevperf.conf -q 64 -o 65536 -w verify -t 10 &
perfpid=$!
waitforlisten $perfpid /var/tmp/bdevperf.sock
$rpc_py -s /var/tmp/bdevperf.sock framework_wait_init
# Expand the trap to clean up bdevperf if something goes wrong
trap 'process_shm --id $NVMF_APP_SHM_ID; kill -9 $perfpid || true; nvmftestfini; exit 1' SIGINT SIGTERM EXIT
waitforio /var/tmp/bdevperf.sock Nvme1n1
# Kill the target half way through
killprocess $nvmfpid
nvmfpid=
# Verify bdevperf exits successfully
sleep 1
# TODO: Right now the NVMe-oF initiator will not correctly detect broken connections
# and so it will never shut down. Just kill it.
kill -9 $perfpid || true
stoptarget
}
nvmftestinit
run_test "nvmf_shutdown_tc1" nvmf_shutdown_tc1
run_test "nvmf_shutdown_tc2" nvmf_shutdown_tc2
run_test "nvmf_shutdown_tc3" nvmf_shutdown_tc3