This patch adds functions in autotest_common.sh, fio_bdev() and fio_nvme() for their respective plugins. It simplifies its usage throughout the scripts. Additionally will help with expanding the fio cmd line with nessecary changes only in single place. This will be used in next patch in series to LD_PRELOAD ASAN before fio_plugin. Note: Did not implement changes for perf scripts, since they are usualy run separately and didn't want to affect those. Similarly didn't change vhost initiator tests, because the exported directories do not work for inside the VM. Will need to think of a way to change it there as well. Change-Id: Idf750ee7aa9d5e30efc0ce430d15fa45ceccb203 Signed-off-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com> Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/456314 Reviewed-by: Konrad Sztyber <konrad.sztyber@intel.com> Reviewed-by: Jim Harris <james.r.harris@intel.com> Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com> Reviewed-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com> Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
87 lines
3.3 KiB
Bash
Executable File
87 lines
3.3 KiB
Bash
Executable File
#!/usr/bin/env bash
|
|
|
|
testdir=$(readlink -f $(dirname $0))
|
|
rootdir=$(readlink -f $testdir/../../..)
|
|
source $rootdir/test/common/autotest_common.sh
|
|
source $rootdir/scripts/common.sh
|
|
source $rootdir/test/nvmf/common.sh
|
|
|
|
rpc_py="$rootdir/scripts/rpc.py"
|
|
|
|
set -e
|
|
|
|
nvmftestinit
|
|
|
|
if [ ! -d /usr/src/fio ]; then
|
|
echo "FIO not available"
|
|
exit 0
|
|
fi
|
|
|
|
timing_enter fio
|
|
timing_enter start_nvmf_tgt
|
|
|
|
$NVMF_APP -m 0xF &
|
|
nvmfpid=$!
|
|
|
|
trap "process_shm --id $NVMF_APP_SHM_ID; nvmftestfini; exit 1" SIGINT SIGTERM EXIT
|
|
|
|
waitforlisten $nvmfpid
|
|
$rpc_py nvmf_create_transport -t $TEST_TRANSPORT -u 8192
|
|
timing_exit start_nvmf_tgt
|
|
|
|
$rpc_py construct_malloc_bdev 64 512 -b Malloc1
|
|
$rpc_py nvmf_subsystem_create nqn.2016-06.io.spdk:cnode1 -a -s SPDK00000000000001
|
|
$rpc_py nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode1 Malloc1
|
|
$rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode1 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_PORT
|
|
|
|
PLUGIN_DIR=$rootdir/examples/nvme/fio_plugin
|
|
|
|
# Test fio_plugin as host with malloc backend
|
|
fio_nvme $PLUGIN_DIR/example_config.fio --filename="trtype=$TEST_TRANSPORT adrfam=IPv4 \
|
|
traddr=$NVMF_FIRST_TARGET_IP trsvcid=$NVMF_PORT ns=1"
|
|
|
|
# second test mocking multiple SGL elements
|
|
fio_nvme $PLUGIN_DIR/mock_sgl_config.fio --filename="trtype=$TEST_TRANSPORT adrfam=IPv4 \
|
|
traddr=$NVMF_FIRST_TARGET_IP trsvcid=$NVMF_PORT ns=1"
|
|
$rpc_py delete_nvmf_subsystem nqn.2016-06.io.spdk:cnode1
|
|
|
|
if [ $RUN_NIGHTLY -eq 1 ]; then
|
|
# Test fio_plugin as host with nvme lvol backend
|
|
bdfs=$(iter_pci_class_code 01 08 02)
|
|
$rpc_py construct_nvme_bdev -b Nvme0 -t PCIe -a $(echo $bdfs | awk '{ print $1 }') -i $NVMF_FIRST_TARGET_IP
|
|
ls_guid=$($rpc_py construct_lvol_store -c 1073741824 Nvme0n1 lvs_0)
|
|
get_lvs_free_mb $ls_guid
|
|
$rpc_py construct_lvol_bdev -l lvs_0 lbd_0 $free_mb
|
|
$rpc_py nvmf_subsystem_create nqn.2016-06.io.spdk:cnode2 -a -s SPDK00000000000001
|
|
$rpc_py nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode2 lvs_0/lbd_0
|
|
$rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode2 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_PORT
|
|
fio_nvme $PLUGIN_DIR/example_config.fio --filename="trtype=$TEST_TRANSPORT adrfam=IPv4 \
|
|
traddr=$NVMF_FIRST_TARGET_IP trsvcid=$NVMF_PORT ns=1"
|
|
$rpc_py delete_nvmf_subsystem nqn.2016-06.io.spdk:cnode2
|
|
|
|
# Test fio_plugin as host with nvme lvol nested backend
|
|
ls_nested_guid=$($rpc_py construct_lvol_store --clear-method none lvs_0/lbd_0 lvs_n_0)
|
|
get_lvs_free_mb $ls_nested_guid
|
|
$rpc_py construct_lvol_bdev -l lvs_n_0 lbd_nest_0 $free_mb
|
|
$rpc_py nvmf_subsystem_create nqn.2016-06.io.spdk:cnode3 -a -s SPDK00000000000001
|
|
$rpc_py nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode3 lvs_n_0/lbd_nest_0
|
|
$rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode3 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_PORT
|
|
fio_nvme $PLUGIN_DIR/example_config.fio --filename="trtype=$TEST_TRANSPORT adrfam=IPv4 \
|
|
traddr=$NVMF_FIRST_TARGET_IP trsvcid=$NVMF_PORT ns=1"
|
|
$rpc_py delete_nvmf_subsystem nqn.2016-06.io.spdk:cnode3
|
|
|
|
sync
|
|
# Delete lvol_bdev and destroy lvol_store.
|
|
$rpc_py destroy_lvol_bdev lvs_n_0/lbd_nest_0
|
|
$rpc_py destroy_lvol_store -l lvs_n_0
|
|
$rpc_py destroy_lvol_bdev lvs_0/lbd_0
|
|
$rpc_py destroy_lvol_store -l lvs_0
|
|
$rpc_py delete_nvme_controller Nvme0
|
|
fi
|
|
|
|
trap - SIGINT SIGTERM EXIT
|
|
|
|
rm -f ./local-test-0-verify.state
|
|
nvmftestfini
|
|
timing_exit fio
|