Currently we fetch the value from the transport
via the admin_qpair. But there are corner cases where
the admin_qpair may be disconnected after an EN=0 or
shutdown process has started.
We could do something like detect if the controller
is being destructed before starting the association
timer, but I think just saving the timeout value in
the ctrlr is a bit cleaner.
Signed-off-by: Jim Harris <james.r.harris@intel.com>
Change-Id: Iaf4ceb2f9d38cee3c9a258e1fdf367972030fbe9
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/6056
Community-CI: Broadcom CI
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: <dongx.yi@intel.com>