Spdk/test/nvmf/target/nmic.sh
Michal Berger 19f0c9a0d0 autotest: Replace fio.py with a bash wrapper in tests
fio.py simply wraps itself around fio and doesn't do anything that
would require python to be in use. Having it in a simple bash form
makes it easier to integrate it with autotest's common sh tooling
and to debug any potential issues with the underlying tests.

This also fixes #1919 by making sure only proper nvme devices are
selected for the nvmf targets.

Fixes: #1919.

Signed-off-by: Michal Berger <michalx.berger@intel.com>
Change-Id: I111d00df3c7b2517f431cae865e258a665c2ecb3
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/7684
Community-CI: Broadcom CI
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
2021-05-12 08:48:10 +00:00

52 lines
1.8 KiB
Bash
Executable File

#!/usr/bin/env bash
testdir=$(readlink -f $(dirname $0))
rootdir=$(readlink -f $testdir/../../..)
source $rootdir/test/common/autotest_common.sh
source $rootdir/test/nvmf/common.sh
MALLOC_BDEV_SIZE=64
MALLOC_BLOCK_SIZE=512
rpc_py="$rootdir/scripts/rpc.py"
nvmftestinit
nvmfappstart -m 0xF
$rpc_py nvmf_create_transport $NVMF_TRANSPORT_OPTS -u 8192
# Create subsystems
$rpc_py bdev_malloc_create $MALLOC_BDEV_SIZE $MALLOC_BLOCK_SIZE -b Malloc0
$rpc_py nvmf_create_subsystem nqn.2016-06.io.spdk:cnode1 -a -s $NVMF_SERIAL
$rpc_py nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode1 Malloc0
$rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode1 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s "$NVMF_PORT"
echo "test case1: single bdev can't be used in multiple subsystems"
$rpc_py nvmf_create_subsystem nqn.2016-06.io.spdk:cnode2 -a -s SPDK2
$rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode2 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s "$NVMF_PORT"
nmic_status=0
$rpc_py nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode2 Malloc0 || nmic_status=$?
if [ $nmic_status -eq 0 ]; then
echo " Adding namespace passed - failure expected."
nvmftestfini
exit 1
else
echo " Adding namespace failed - expected result."
fi
echo "test case2: host connect to nvmf target in multiple paths"
$rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode1 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s "$NVMF_SECOND_PORT"
nvme connect -t $TEST_TRANSPORT -n "nqn.2016-06.io.spdk:cnode1" -a "$NVMF_FIRST_TARGET_IP" -s "$NVMF_PORT"
nvme connect -t $TEST_TRANSPORT -n "nqn.2016-06.io.spdk:cnode1" -a "$NVMF_FIRST_TARGET_IP" -s "$NVMF_SECOND_PORT"
waitforserial "$NVMF_SERIAL"
$rootdir/scripts/fio-wrapper -p nvmf -i 4096 -d 1 -t write -r 1 -v
nvme disconnect -n "nqn.2016-06.io.spdk:cnode1"
trap - SIGINT SIGTERM EXIT
nvmftestfini