Spdk/test/nvmf/target/multiconnection.sh
Seth Howell 1fafd71bc3 test: add timing calls to run_test
And clean out the corresponding calls to timing_enter and timing_exit
from the various test scripts.

Change-Id: I0759417b5a529e4c3649ce04cca1799c089da278
Signed-off-by: Seth Howell <seth.howell@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/476804
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Community-CI: Broadcom SPDK FC-NVMe CI <spdk-ci.pdl@broadcom.com>
2019-12-10 17:12:03 +00:00

57 lines
1.6 KiB
Bash
Executable File

#!/usr/bin/env bash
testdir=$(readlink -f $(dirname $0))
rootdir=$(readlink -f $testdir/../../..)
source $rootdir/test/common/autotest_common.sh
source $rootdir/test/nvmf/common.sh
MALLOC_BDEV_SIZE=64
MALLOC_BLOCK_SIZE=512
NVMF_SUBSYS=11
rpc_py="$rootdir/scripts/rpc.py"
nvmftestinit
nvmfappstart "-m 0xF"
# SoftRoce does not have enough queues available for
# multiconnection tests. Detect if we're using software RDMA.
# If so - lower the number of subsystems for test.
if check_ip_is_soft_roce $NVMF_FIRST_TARGET_IP; then
echo "Using software RDMA, lowering number of NVMeOF subsystems."
NVMF_SUBSYS=1
fi
$rpc_py nvmf_create_transport $NVMF_TRANSPORT_OPTS -u 8192
for i in $(seq 1 $NVMF_SUBSYS)
do
$rpc_py bdev_malloc_create $MALLOC_BDEV_SIZE $MALLOC_BLOCK_SIZE -b Malloc$i
$rpc_py nvmf_create_subsystem nqn.2016-06.io.spdk:cnode$i -a -s SPDK$i
$rpc_py nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode$i Malloc$i
$rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode$i -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_PORT
done
for i in $(seq 1 $NVMF_SUBSYS); do
k=$((i-1))
nvme connect -t $TEST_TRANSPORT -n "nqn.2016-06.io.spdk:cnode${i}" -a "$NVMF_FIRST_TARGET_IP" -s "$NVMF_PORT"
waitforblk "nvme${k}n1"
done
$rootdir/scripts/fio.py -p nvmf -i 262144 -d 64 -t read -r 10
$rootdir/scripts/fio.py -p nvmf -i 262144 -d 64 -t randwrite -r 10
sync
for i in $(seq 1 $NVMF_SUBSYS); do
nvme disconnect -n "nqn.2016-06.io.spdk:cnode${i}" || true
$rpc_py nvmf_delete_subsystem nqn.2016-06.io.spdk:cnode${i}
done
rm -f ./local-job0-0-verify.state
trap - SIGINT SIGTERM EXIT
nvmftestfini