Spdk/test/nvmf/host/bdevperf.sh
Jim Harris 41456afc3c test/nvmf: simplify more of the nvmf test scripts
This should cover all of the cases that we want to
changes for now - where it was doing an unnecessarily
loop over just one malloc bdev.

A few cases remain, but I'm planning to strengthen
those tests with more bdevs.

Signed-off-by: Jim Harris <james.r.harris@intel.com>
Change-Id: I16f9e82b4a551bcf1f491fc506e11c0ee98b60d9
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/452917
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Seth Howell <seth.howell5141@gmail.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
2019-05-06 05:46:12 +00:00

55 lines
1.7 KiB
Bash
Executable File

#!/usr/bin/env bash
testdir=$(readlink -f $(dirname $0))
rootdir=$(readlink -f $testdir/../../..)
source $rootdir/test/common/autotest_common.sh
source $rootdir/test/nvmf/common.sh
MALLOC_BDEV_SIZE=64
MALLOC_BLOCK_SIZE=512
rpc_py="$rootdir/scripts/rpc.py"
set -e
# pass the parameter 'iso' to this script when running it in isolation to trigger rdma device initialization.
# e.g. sudo ./bdevperf.sh iso
nvmftestinit $1
RDMA_IP_LIST=$(get_available_rdma_ips)
NVMF_FIRST_TARGET_IP=$(echo "$RDMA_IP_LIST" | head -n 1)
if [ -z $NVMF_FIRST_TARGET_IP ]; then
echo "no NIC for nvmf test"
exit 0
fi
timing_enter bdevperf
timing_enter start_nvmf_tgt
$NVMF_APP -m 0xF &
nvmfpid=$!
trap "process_shm --id $NVMF_APP_SHM_ID; killprocess $nvmfpid; nvmftestfini $1; exit 1" SIGINT SIGTERM EXIT
waitforlisten $nvmfpid
$rpc_py nvmf_create_transport -t RDMA -u 8192 -p 4
timing_exit start_nvmf_tgt
$rpc_py construct_malloc_bdev $MALLOC_BDEV_SIZE $MALLOC_BLOCK_SIZE -b Malloc0
$rpc_py nvmf_subsystem_create nqn.2016-06.io.spdk:cnode1 -a -s SPDK00000000000001
$rpc_py nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode1 Malloc0
$rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode1 -t rdma -a $NVMF_FIRST_TARGET_IP -s 4420
echo "[Nvme]" > $testdir/bdevperf.conf
echo " TransportID \"trtype:RDMA adrfam:IPv4 subnqn:nqn.2016-06.io.spdk:cnode1 traddr:$NVMF_FIRST_TARGET_IP trsvcid:4420\" Nvme0" >> $testdir/bdevperf.conf
$rootdir/test/bdev/bdevperf/bdevperf -c $testdir/bdevperf.conf -q 128 -o 4096 -w verify -t 1
sync
rm -rf $testdir/bdevperf.conf
$rpc_py delete_nvmf_subsystem nqn.2016-06.io.spdk:cnode1
trap - SIGINT SIGTERM EXIT
killprocess $nvmfpid
nvmftestfini $1
timing_exit bdevperf