Spdk/test/nvmf/target/nvmf_vfio_user.sh
Changpeng 3ff9c13614 NVMe/vfio-user: add initial version vfio-user transport to NVMe driver
When NVMf target linked with vfio-user library, we can use
vfio-user client library to connect to the target.

Here is the three examples that can work with target:

identify -r 'trtype:VFIOUSER traddr:/var/run/muser/domain/muser0/8' -g
perf -r 'trtype:VFIOUSER traddr:/var/run/muser/domain/muser0/8' -g -q 1 -o 4096 -w read -t 10
reconnect -r 'trtype:VFIOUSER traddr:/var/run/muser/domain/muser0/8' -g -q 32 -o 4096 -w randrw \
-M 50 -t 10 -c 0xE

You can run the following test script test/nvmf/target/nvmf_vfio_user.sh to have a quick test,
currently enabled with NVMe Identify,Perf,Reconnect tools.

Change-Id: Ieb9842b2f372184fffbf7f23e4aad26feb47c350
Signed-off-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/3839
Community-CI: Broadcom CI
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
2021-01-21 05:00:18 +00:00

59 lines
1.8 KiB
Bash
Executable File

#!/usr/bin/env bash
testdir=$(readlink -f $(dirname $0))
rootdir=$(readlink -f $testdir/../../..)
source $rootdir/test/common/autotest_common.sh
source $rootdir/test/nvmf/common.sh
MALLOC_BDEV_SIZE=512
MALLOC_BLOCK_SIZE=512
rpc_py="$rootdir/scripts/rpc.py"
export TEST_TRANSPORT=VFIOUSER
rm -rf /var/run/muser
rm -rf /dev/shm/muser
mkdir -p /var/run/muser
mkdir -p /var/run/muser/iommu_group
mkdir -p /var/run/muser/domain/muser0/8
mkdir -p /dev/shm/muser/muser0
# Start the target
"${NVMF_APP[@]}" -m 0x1 &
nvmfpid=$!
echo "Process pid: $nvmfpid"
trap 'killprocess $nvmfpid; exit 1' SIGINT SIGTERM EXIT
waitforlisten $nvmfpid
sleep 1
$rpc_py nvmf_create_transport -t VFIOUSER
$rpc_py bdev_malloc_create $MALLOC_BDEV_SIZE $MALLOC_BLOCK_SIZE -b Malloc0
$rpc_py nvmf_create_subsystem nqn.2019-07.io.spdk:cnode0 -a -s SPDK0
$rpc_py nvmf_subsystem_add_ns nqn.2019-07.io.spdk:cnode0 Malloc0
$rpc_py nvmf_subsystem_add_listener nqn.2019-07.io.spdk:cnode0 -t VFIOUSER -a "/var/run/muser/domain/muser0/8" -s 0
ln -s /var/run/muser/domain/muser0/8 /var/run/muser/domain/muser0/8/iommu_group
ln -s /var/run/muser/domain/muser0/8 /var/run/muser/iommu_group/8
ln -s /var/run/muser/domain/muser0/8/bar0 /dev/shm/muser/muser0/bar0
$SPDK_EXAMPLE_DIR/identify -r 'trtype:VFIOUSER traddr:/var/run/muser/domain/muser0/8' -g -L nvme -L nvme_vfio -L vfio_pci
sleep 1
$SPDK_EXAMPLE_DIR/perf -r 'trtype:VFIOUSER traddr:/var/run/muser/domain/muser0/8' -s 256 -g -q 128 -o 4096 -w read -t 10 -c 0x2
sleep 1
$SPDK_EXAMPLE_DIR/perf -r 'trtype:VFIOUSER traddr:/var/run/muser/domain/muser0/8' -s 256 -g -q 128 -o 4096 -w write -t 10 -c 0x2
sleep 1
$SPDK_EXAMPLE_DIR/reconnect -r 'trtype:VFIOUSER traddr:/var/run/muser/domain/muser0/8' -g -q 32 -o 4096 -w randrw -M 50 -t 10 -c 0xE
sleep 1
killprocess $nvmfpid
rm -rf /var/run/muser
rm -rf /dev/shm/muser
trap - SIGINT SIGTERM EXIT