Spdk/test/nvmf/host/failover.sh
Krzysztof Karas 29784f35cd bdevperf: promote bdevperf from test to example application
bdevperf application is utilized in multiple test scenarios
and most prominently in SPDK performance reports.
Similar to perf and fio_plugins, it is used to measure performance.
It is intended to represent the expected behavior of users
application that use SPDK bdev layer.

Applications under --enable-tests are intended for specific test
scenarios and user interaction is usually via a test scripts.
Meanwhile --enable-examples are used more broadly to teach and
show usage of SPDK libraries.

As an added benefit with this patch, its possible to compile
bdevperf without need to satisfy additional requirements to
compile all the test applications.

Change-Id: I9aaec1f9d729a1cdee89b5fdc365d61c19b03f82
Signed-off-by: Krzysztof Karas <krzysztof.karas@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/14558
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@nvidia.com>
Reviewed-by: Paul Luse <paul.e.luse@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Mellanox Build Bot
2022-11-16 09:52:41 +00:00

114 lines
5.2 KiB
Bash
Executable File

#!/usr/bin/env bash
testdir=$(readlink -f $(dirname $0))
rootdir=$(readlink -f $testdir/../../..)
source $rootdir/test/common/autotest_common.sh
source $rootdir/test/nvmf/common.sh
MALLOC_BDEV_SIZE=64
MALLOC_BLOCK_SIZE=512
rpc_py="$rootdir/scripts/rpc.py"
bdevperf_rpc_sock=/var/tmp/bdevperf.sock
nvmftestinit
nvmfappstart -m 0xE
$rpc_py nvmf_create_transport $NVMF_TRANSPORT_OPTS -u 8192
$rpc_py bdev_malloc_create $MALLOC_BDEV_SIZE $MALLOC_BLOCK_SIZE -b Malloc0
$rpc_py nvmf_create_subsystem nqn.2016-06.io.spdk:cnode1 -a -s SPDK00000000000001
$rpc_py nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode1 Malloc0
$rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode1 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_PORT
$rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode1 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_SECOND_PORT
$rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode1 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_THIRD_PORT
$rootdir/build/examples/bdevperf -z -r $bdevperf_rpc_sock -q 128 -o 4096 -w verify -t 10 -f &> $testdir/try.txt &
bdevperf_pid=$!
trap 'process_shm --id $NVMF_APP_SHM_ID; cat $testdir/try.txt; rm -f $testdir/try.txt; killprocess $bdevperf_pid; nvmftestfini; exit 1' SIGINT SIGTERM EXIT
waitforlisten $bdevperf_pid $bdevperf_rpc_sock
$rpc_py -s $bdevperf_rpc_sock bdev_nvme_attach_controller -b NVMe0 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_PORT -f ipv4 -n nqn.2016-06.io.spdk:cnode1
$rpc_py -s $bdevperf_rpc_sock bdev_nvme_attach_controller -b NVMe0 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_SECOND_PORT -f ipv4 -n nqn.2016-06.io.spdk:cnode1
$rootdir/examples/bdev/bdevperf/bdevperf.py -s $bdevperf_rpc_sock perform_tests &
run_test_pid=$!
sleep 1
$rpc_py nvmf_subsystem_remove_listener nqn.2016-06.io.spdk:cnode1 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_PORT
sleep 3
$rpc_py -s $bdevperf_rpc_sock bdev_nvme_attach_controller -b NVMe0 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_THIRD_PORT -f ipv4 -n nqn.2016-06.io.spdk:cnode1
$rpc_py nvmf_subsystem_remove_listener nqn.2016-06.io.spdk:cnode1 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_SECOND_PORT
sleep 3
# Give the admin qpair time to fail before we add the new listener in. This prevents us from trying to connect to the wrong trid.
$rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode1 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_PORT
sleep 1
$rpc_py nvmf_subsystem_remove_listener nqn.2016-06.io.spdk:cnode1 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_THIRD_PORT
wait $run_test_pid
killprocess $bdevperf_pid
cat $testdir/try.txt
# if this test fails it means we didn't fail over to the second
count="$(grep -c "Resetting controller successful" < $testdir/try.txt)"
if ((count != 3)); then
false
fi
# Part 2 of the test. Start removing ports, starting with the one we are connected to, confirm that the ctrlr remains active until the final trid is removed.
$rootdir/build/examples/bdevperf -z -r $bdevperf_rpc_sock -q 128 -o 4096 -w verify -t 1 -f &> $testdir/try.txt &
bdevperf_pid=$!
waitforlisten $bdevperf_pid $bdevperf_rpc_sock
$rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode1 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_SECOND_PORT
$rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode1 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_THIRD_PORT
$rpc_py -s $bdevperf_rpc_sock bdev_nvme_attach_controller -b NVMe0 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_PORT -f ipv4 -n nqn.2016-06.io.spdk:cnode1
$rpc_py -s $bdevperf_rpc_sock bdev_nvme_attach_controller -b NVMe0 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_SECOND_PORT -f ipv4 -n nqn.2016-06.io.spdk:cnode1
$rpc_py -s $bdevperf_rpc_sock bdev_nvme_attach_controller -b NVMe0 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_THIRD_PORT -f ipv4 -n nqn.2016-06.io.spdk:cnode1
$rpc_py -s $bdevperf_rpc_sock bdev_nvme_get_controllers | grep -q NVMe0
$rpc_py -s $bdevperf_rpc_sock bdev_nvme_detach_controller NVMe0 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_PORT -f ipv4 -n nqn.2016-06.io.spdk:cnode1
# Async operation since we need to reconnect with new TRID.
sleep 3
$rpc_py -s $bdevperf_rpc_sock bdev_nvme_get_controllers | grep -q NVMe0
$rootdir/examples/bdev/bdevperf/bdevperf.py -s $bdevperf_rpc_sock perform_tests &
run_test_pid=$!
wait $run_test_pid
cat $testdir/try.txt
$rpc_py -s $bdevperf_rpc_sock bdev_nvme_get_controllers | grep -q NVMe0
# No need to wait here since we are deleting a TRID we aren't connected to.
$rpc_py -s $bdevperf_rpc_sock bdev_nvme_detach_controller NVMe0 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_THIRD_PORT -f ipv4 -n nqn.2016-06.io.spdk:cnode1
$rpc_py -s $bdevperf_rpc_sock bdev_nvme_get_controllers | grep -q NVMe0
$rpc_py -s $bdevperf_rpc_sock bdev_nvme_detach_controller NVMe0 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_SECOND_PORT -f ipv4 -n nqn.2016-06.io.spdk:cnode1
sleep 3
if $rpc_py -s $bdevperf_rpc_sock bdev_nvme_get_controllers | grep -q NVMe0; then
echo "Controller was not properly removed."
false
fi
killprocess $bdevperf_pid
sync
$rpc_py nvmf_delete_subsystem nqn.2016-06.io.spdk:cnode1
trap - SIGINT SIGTERM EXIT
rm -f $testdir/try.txt
nvmftestfini