#!/usr/bin/env bash testdir=$(readlink -f $(dirname $0)) rootdir=$(readlink -f $testdir/../../..) source $rootdir/test/common/autotest_common.sh source $rootdir/scripts/common.sh source $rootdir/test/nvmf/common.sh rpc_py="$rootdir/scripts/rpc.py" nvmftestinit if [ ! -d /usr/src/fio ]; then echo "FIO not available" exit 1 fi timing_enter fio timing_enter start_nvmf_tgt $NVMF_APP -m 0xF & nvmfpid=$! trap "process_shm --id $NVMF_APP_SHM_ID; nvmftestfini; exit 1" SIGINT SIGTERM EXIT waitforlisten $nvmfpid $rpc_py nvmf_create_transport $NVMF_TRANSPORT_OPTS -u 8192 timing_exit start_nvmf_tgt $rpc_py construct_malloc_bdev 64 512 -b Malloc1 $rpc_py nvmf_subsystem_create nqn.2016-06.io.spdk:cnode1 -a -s SPDK00000000000001 $rpc_py nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode1 Malloc1 $rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode1 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_PORT PLUGIN_DIR=$rootdir/examples/nvme/fio_plugin # Test fio_plugin as host with malloc backend fio_nvme $PLUGIN_DIR/example_config.fio --filename="trtype=$TEST_TRANSPORT adrfam=IPv4 \ traddr=$NVMF_FIRST_TARGET_IP trsvcid=$NVMF_PORT ns=1" # second test mocking multiple SGL elements fio_nvme $PLUGIN_DIR/mock_sgl_config.fio --filename="trtype=$TEST_TRANSPORT adrfam=IPv4 \ traddr=$NVMF_FIRST_TARGET_IP trsvcid=$NVMF_PORT ns=1" $rpc_py delete_nvmf_subsystem nqn.2016-06.io.spdk:cnode1 if [ $RUN_NIGHTLY -eq 1 ]; then # Test fio_plugin as host with nvme lvol backend bdfs=$(iter_pci_class_code 01 08 02) $rpc_py construct_nvme_bdev -b Nvme0 -t PCIe -a $(echo $bdfs | awk '{ print $1 }') -i $NVMF_FIRST_TARGET_IP ls_guid=$($rpc_py construct_lvol_store -c 1073741824 Nvme0n1 lvs_0) get_lvs_free_mb $ls_guid $rpc_py construct_lvol_bdev -l lvs_0 lbd_0 $free_mb $rpc_py nvmf_subsystem_create nqn.2016-06.io.spdk:cnode2 -a -s SPDK00000000000001 $rpc_py nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode2 lvs_0/lbd_0 $rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode2 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_PORT fio_nvme $PLUGIN_DIR/example_config.fio --filename="trtype=$TEST_TRANSPORT adrfam=IPv4 \ traddr=$NVMF_FIRST_TARGET_IP trsvcid=$NVMF_PORT ns=1" $rpc_py delete_nvmf_subsystem nqn.2016-06.io.spdk:cnode2 # Test fio_plugin as host with nvme lvol nested backend ls_nested_guid=$($rpc_py construct_lvol_store --clear-method none lvs_0/lbd_0 lvs_n_0) get_lvs_free_mb $ls_nested_guid $rpc_py construct_lvol_bdev -l lvs_n_0 lbd_nest_0 $free_mb $rpc_py nvmf_subsystem_create nqn.2016-06.io.spdk:cnode3 -a -s SPDK00000000000001 $rpc_py nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode3 lvs_n_0/lbd_nest_0 $rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode3 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_PORT fio_nvme $PLUGIN_DIR/example_config.fio --filename="trtype=$TEST_TRANSPORT adrfam=IPv4 \ traddr=$NVMF_FIRST_TARGET_IP trsvcid=$NVMF_PORT ns=1" $rpc_py delete_nvmf_subsystem nqn.2016-06.io.spdk:cnode3 sync # Delete lvol_bdev and destroy lvol_store. $rpc_py destroy_lvol_bdev lvs_n_0/lbd_nest_0 $rpc_py destroy_lvol_store -l lvs_n_0 $rpc_py destroy_lvol_bdev lvs_0/lbd_0 $rpc_py destroy_lvol_store -l lvs_0 $rpc_py delete_nvme_controller Nvme0 fi trap - SIGINT SIGTERM EXIT rm -f ./local-test-0-verify.state nvmftestfini timing_exit fio