A single I/O may allocate more than one request, since splitting may be
necessary to conform to the device's maximum transfer size, PRP list
compatibility requirements, or driver-assisted striping. Very big
I/O request sent from application may get error due to limited resources
in NVMe driver layer, so here we add an optional parameter to make the
parameter can be configured by users.
Fix issue #745.
Change-Id: I7824232c54865b052dcd0ec6e91484c3837fc2c4
Signed-off-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/461182
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
On multiple development systems (including mine), this results
in new error messages when running scripts/setup.sh. This has
the potential of causing lots of questions when users upgrade
to SPDK 19.07.
I understand the desire for the error messages, but I think we have
to come up with a smarter check than just against "unlimited".
This reverts commit 0abee610f0.
Signed-off-by: Jim Harris <james.r.harris@intel.com>
Change-Id: I2854af556b67a9a4e5f686c72c4407962808f964
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/463357
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
This internal tool can now be passed an optional --cross-prefix,
which sets up the prefix used for a cross compiler.
Change-Id: Ia4bbbae3bd5a2e4ddc9da342cd03d600e9ee6099
Signed-off-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/463016
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Reviewed-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com>
Reviewed-by: Paul Luse <paul.e.luse@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
We need to know this up front.
Change-Id: I3a9ceb90cf62eacbf3fdf518a9ccb4c4978b3a05
Signed-off-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/463014
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Reviewed-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com>
Reviewed-by: Paul Luse <paul.e.luse@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Arguments for this function were added as optional arguments
and were listed as such by argparse when using rpc.py --help.
This is confusing as all of these arguments are obligatory
in order to create a crypto bdev in SPDK configuration.
Change-Id: I7c31413314f28e44ee008d3d7c28759063700b61
Signed-off-by: Karol Latecki <karol.latecki@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/460968
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Vitaliy Mysak <vitaliy.mysak@intel.com>
Reviewed-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com>
Reviewed-by: Pawel Kaminski <pawelx.kaminski@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Added parsing and saving of (optional) parameters which are responsible for
relocation in FTL. Changing the parameters may affect Write
Amplification Factor and overall performance, especially during random
write workloads. If parameters are not specified, default values will be used.
Signed-off-by: Mateusz Kozlowski <mateusz.kozlowski@intel.com>
Change-Id: Ic0229e39109460f3541c31e1cbf2a485efe408c6
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/460504
Reviewed-by: Konrad Sztyber <konrad.sztyber@intel.com>
Reviewed-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Catch exceptions during RPC client initialization
to display meaningful error message.
Withouth this change, user gets stacktrace
when e.g. SPDK application is not running.
Before:
```
Traceback (most recent call last):
File "scripts/rpc/client.py", line 53, in __init__
raise socket.error("Unix socket '%s' does not exist" % addr)
OSError: Unix socket '/var/tmp/spdk.sock' does not exist
During handling of the above exception, another exception occurred:
Traceback (most recent call last):
File "scripts/spdkcli.py", line 74, in <module>
main()
File "scripts/spdkcli.py", line 47, in main
with rpc.client.JSONRPCClient(args.socket) as client:
File "scripts/rpc/client.py", line 56, in __init__
"Error details: %s" % (addr, ex))
rpc.client.JSONRPCException: Error while connecting to /var/tmp/spdk.sock
Error details: Unix socket '/var/tmp/spdk.sock' does not exist
```
After:
```
Error while connecting to /var/tmp/spdk.sock
Error details: Unix socket '/var/tmp/spdk.sock' does not exist. SPDK not running?
```
Change-Id: I65862965b68acf3bd4709de598f04de49da27de2
Signed-off-by: Vitaliy Mysak <vitaliy.mysak@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/462020
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Karol Latecki <karol.latecki@intel.com>
Reviewed-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
RPC client constructor accepts optional port,
but does not check if it's None in case of
remote connection.
This patch adds the check and new error message
related to it.
Case where port is unexpectedly None
can be reproduced by starting spdkcli
when SPDK socket does not exist.
Change-Id: I46e0b99547204c6fdeac421e5de9d6991387e207
Signed-off-by: Vitaliy Mysak <vitaliy.mysak@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/460974
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com>
Reviewed-by: Karol Latecki <karol.latecki@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
This priority is used to differentiate the sock priority on the TCP connections
between NVMe-oF TCP target and other TCP based applications.
Signed-off-by: Ziye Yang <ziye.yang@intel.com>
Change-Id: I6ee294e647420b56d1d91a07c2e37bf34ce24e03
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/461801
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
JSONRPCClient.call recieved optional `params` value,
but then `params` was used in `json.dumps` function (line #159)
as a dictionary, so `None` was treated as dictionary
in some cases, which resulted in TypeError.
This patch fixes above issue by changing
the default value from `None` to `{}`.
Change-Id: I27ca0ccc2d970c0ff9e8117f02203c03e417adf0
Signed-off-by: Vitaliy Mysak <vitaliy.mysak@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/462070
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Currently we do not switch driver for NVMe that is mounted.
The problem is that we take into consideration only the
first namespace, but any other namespace can be still mounted.
In such case we should not switch driver.
Signed-off-by: Maciej Szwed <maciej.szwed@intel.com>
Change-Id: Idd13edccd0929574f2914a71e841e67871dd2e9f
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/457762
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Karol Latecki <karol.latecki@intel.com>
Reviewed-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Purpose: To eanble the transport based scheduler in RPC.
Previously, we only support it with configuration file.
Signed-off-by: Ziye Yang <ziye.yang@intel.com>
Change-Id: I02ae9b1b316d4fec8b28b550e70dcdc78ce78722
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/461645
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
This option was intended to enable the user to disable the c2h_option,
but because of the way arguments filter down through the python script,
it was actually impossible to disable the optimization.
My understanding is that typically we will want to keep this
optimization enabled on most systems, but the option should work like it
says it does.
Also, align the implementation of this function with the other ones on
the RPC i.e. use the store_true, store_false paradigm.
Change-Id: I59f0e9a573abf1d567e5539294c63c68899b35f1
Signed-off-by: Seth Howell <seth.howell@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/461737
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
`pmem_pool_info` was incorrectly set to invoke
`delete_pmem_pool` RPC method.
The name of command was also incorrect - "info_pmem_pool"
instead of "pmem_pool_info", where
latter is the original name of RPC method.
This patch fixes both issues with `pmem_pool_info`.
This bug has not been caught because
there are no tests for `pmem_pool_info` command yet.
Change-Id: Icc207bc3a7cf6c817cb079137d7b473f52186a84
Signed-off-by: Vitaliy Mysak <vitaliy.mysak@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/460840
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Karol Latecki <karol.latecki@intel.com>
Reviewed-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com>
This patch adds nvmf_get_stats RPC method and basic infrastructure to
report NVMf global and per poll group statistics in JSON format.
Signed-off-by: Evgeniy Kochetov <evgeniik@mellanox.com>
Change-Id: I13b83e28b75a02bc1dcb7b95cbce52ae10ff0f7b
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/452298
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com>
This patch excludes *.patch files from some checks in check_format.sh:
- trailing spaces,
- POSIX includes
Change-Id: Ic55ce7f4128ddc946d235b4ca487061075edc03b
Signed-off-by: Tomasz Kulasek <tomaszx.kulasek@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/460939
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Reviewed-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Paul Luse <paul.e.luse@intel.com>
Add an new optional parameter dif_insert_or_strip to
nvmf_create_transport RPC.
.INI config file will be deprecated and dif_insert_or_strip is not
supported in .INI config file.
Change-Id: Ibf38b599cff75eeb0056dd2125d6ec10d444f339
Signed-off-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/458927
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Paul Luse <paul.e.luse@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Scripts were using a mix of two approaches, lets unify that so
just dollar-parenthesis syntax is used.
Also update two scripts from spdk/test which we previously missed.
Change-Id: I429f9bc158076462b419fae597f716c329f9b7aa
Signed-off-by: Karol Latecki <karol.latecki@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/460344
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
There will be one more "mocked" implementation soon,
so make existing names more descriptive now.
Change-Id: I30daf2b60ab683d5befb06eca50d455712858d61
Signed-off-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/459390
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
The previous name wasn't very accurate. The function
accepts a json object, so call it print_json().
Change-Id: If1cae587fd13f0a8a2761049125fc7fb234c0360
Signed-off-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/459388
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Also, construct this path by grabbing the home directory
of the current user.
Change-Id: Ia8d5cc2be40c0c3ac693c80a3132b970f7124183
Signed-off-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/456704
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Changed initialization of the ftl lib when using an rpc call to
allow for usage of any default configuration parameters (currently
only allow_open_bands is exposed).
Signed-off-by: Mateusz Kozlowski <mateusz.kozlowski@intel.com>
Change-Id: I73457dfcacc6b1adeffd13ecc6e98001749e00cf
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/459741
Reviewed-by: Konrad Sztyber <konrad.sztyber@intel.com>
Reviewed-by: Wojciech Malikowski <wojciech.malikowski@intel.com>
Reviewed-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
By default QAT will be selected if available however a new RPC
can be used to either auto-select (default) or specify either
ISAL or QAT.
Change-Id: I37cf7640bbd8cef455583e1eccb8adb59cc419d8
Signed-off-by: paul luse <paul.e.luse@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/456693
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com>
By now (5.1 is released), the Linux kernel initiator supports the
success optimization and further, the version that doesn't support
it (5.0) was EOL-ed. As such, lets open it up @ spdk by default.
Doing so provides a notable performance improvement: running perf with
iodepth of 64, randread, two threads and block size of 512 bytes for 60s
("-q 64 -w randread -o 512 -c 0x5000 -t 60") over the VMA socket acceleration
library and null backing store, we got 730K IOPS with the success
optimization vs 550K without it.
IOPS MiB/s Average min max
549274.10 268.20 232.99 93.23 3256354.96
728117.57 355.53 175.76 85.93 14632.16
To allow for interop with older kernel initiators, we added
a config knob under which the success optimization can be
enabled or disabled.
Change-Id: Ia4c79f607f82c3563523ae3e07a67eac95b56dbb
Signed-off-by: Or Gerlitz <ogerlitz@mellanox.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/457644
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Ziye Yang <ziye.yang@intel.com>
Reviewed-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com>
Removing Fedora 26 and 27 which are long past their EOL date.
Adding Fedora 29 and 30.
Change-Id: I35bc8b7a5ac693b7a5af0e6abb35869b18ed5777
Signed-off-by: Karol Latecki <karol.latecki@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/457924
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: yidong0635 <dongx.yi@intel.com>
Reviewed-by: Pawel Kaminski <pawelx.kaminski@intel.com>
Reviewed-by: Paul Luse <paul.e.luse@intel.com>
Reviewed-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
The next patch in this series introduces and RPC that makes the
selection more flexible.
Signed-off-by: paul luse <paul.e.luse@intel.com>
Change-Id: I55617d3c37b51cf9474c358cb92f5218397c0c58
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/457157
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com>
Report issue on ubuntu18 :
"spdk/autobuild.sh: line 55: hash: scan-build: not found"
Check that ubuntu18 should install this package:
apt-get install -y clang-tools, to fit version of ubuntu18
and later.
Move clang-analyzer which for fedora to vm_setup.sh as well.
Change-Id: Ia702c492f8b0f64705c7c15ee57a861ca14521f9
signed-off-by: yidong0635 <dongx.yi@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/457554
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Karol Latecki <karol.latecki@intel.com>
Reviewed-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com>
Missing try-except block around call_rpc_func().
If called function returned error there was an uncaught exception
which resulted in backtrace printed to screen.
Change-Id: Ifb37c29d70b93ef648a0503643a51cc1967ef8d0
Signed-off-by: Karol Latecki <karol.latecki@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/456956
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com>
Gives the ability to change behavior of restore after dirty shutdown
without recompiling ftl library. User can define if partial recovery
or error should be returned after such a scenario.
Signed-off-by: Mateusz Kozlowski <mateusz.kozlowski@intel.com>
Change-Id: I6dda40df7b92d6a377957e4a70a3eab91a6ac4a9
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/456185
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Konrad Sztyber <konrad.sztyber@intel.com>
Make construct_ocf_bdev call accept 'wb'
as allowed cache mode.
Previusly user could only create OCF bdevs
in WriteThrough or PassThrough modes.
Change-Id: Ic2e1c8d2905cb51fc13c080aa7b7a4dfd7d9387f
Signed-off-by: Vitaliy Mysak <vitaliy.mysak@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/455628
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
This change will allow easier debugging of
what parameters are sent to spdk target.
It will also help to analyse which commands will fail
if multiple commands are sent to rpc.py.
Change-Id: I8e75b5edce791a1fc41e83664add8893f4c1bbfb
Signed-off-by: Pawel Kaminski <pawelx.kaminski@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/455636
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
This script was getting a bit unwieldy. adding argparse will make it
easier to add more options in the future or to set default values and
validate arguments going forward.
Change-Id: I1ffdbdf2082287ceb8a88cd3eb6ecf9bbd6c9e11
Signed-off-by: Seth Howell <seth.howell@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/455724
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com>
This module simply sits on another virtual bdev
and adds a simulated average and p99 latency to that drive.
Change-Id: Ie9fc91e27585fd0636cb7dc845cb41744bf24625
Signed-off-by: Seth Howell <seth.howell@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/453594
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com>
Fixed the following:
1) Missing python paramiko module in package dependecies.
2) Paramiko connection error: TypeError: missing_host_key() missing 1 required positional argument: 'key'
The set_missing_host_key_policy call should take a class instance AutoAddPolicy(), instead of the class name.
3) JSON config file defines "rdma_ips" instead of "nic_ips"
4) Added result file location in the documentation
5) Added env variable for PYTHONPATH to documentation
6) config.json changed default rw to randrw instead of read
Change-Id: I96624e2912131f62254c684a6c03a53a7f806cde
Signed-off-by: John Kariuki <John.K.Kariuki@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/455285
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Liang Yan <liang.z.yan@intel.com>
After iSCSI login sysfs is not updated immediately, but when session is
initialized. It can take a while and causes that sometimes scripts
cannot write to sysfs.
Change-Id: Ie4fa512704f022041bb3d9ab02dbb4210ddd04a0
Signed-off-by: Tomasz Kulasek <tomaszx.kulasek@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/454890
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Reviewed-by: Maciej Szwed <maciej.szwed@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
To bind VMD device it need to be specified
in PCI_WHITELIST.
Change-Id: If19c47941278e4df9c6157024bba8b76c90695c6
Signed-off-by: Wojciech Malikowski <wojciech.malikowski@intel.com>
Signed-off-by: Orden Smith <orden.e.smith@intel.com>
Signed-off-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/455635
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Make the old name a deprecated alias.
Signed-off-by: Jim Harris <james.r.harris@intel.com>
Change-Id: Ibbf50676e0d989b67121e465fc140f94faec46ed
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/453033
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
This is a bit more flexible in case script accidentally
has an extra newline at the end of the rpc.py input.
Signed-off-by: Jim Harris <james.r.harris@intel.com>
Change-Id: I1ebf08681e5900a4817712c7b62e4d5c21d43e54
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/453956
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Karol Latecki <karol.latecki@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Adds support to spdkcli.py for raid devices via UIRaidBdev with
functionality to construct and destroy raid bdevs.
Information regarding the raid can be viewed via 'show_details' on a
given pooled_device child in the tree.
Signed-off-by: Mike Carlin <mikefcarlin@protonmail.com>
Change-Id: I2ca89e641b201c09b3d4db070eac6cc0c2cdec73
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/452774
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Pawel Kaminski <pawelx.kaminski@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
We marked the old set/clear/get_trace_flags as
deprecated in v19.01. These are now called
set/clear/get_log_flags (to reduce confusion with the
tracing framework). Use the new methods in this
patch series to mark these RPCs as deprecated.
Signed-off-by: Jim Harris <james.r.harris@intel.com>
Change-Id: I5ce8992ce8f6c1de5d5596b5f94a1587555e8546
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/453563
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
This will get used in upcoming patches that actually
create RPC aliases.
Thanks to Ben Walker for help on the deprecated_alias
helper.
Signed-off-by: Jim Harris <james.r.harris@intel.com>
Change-Id: Ica4432888b1ecb9bd234690758f67ef82794c50a
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/453035
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Ordinary python str.split() will by default split on each whitespace.
This includes arguments for rpc.py which expect a whitespace separated list,
eg. construct_raid_bdev -b "Bdev_1 Bdev_2".
shlex.split() prevents splitting on quoted arguments.
Change-Id: If37eb87cf82a161263f2b247baff5c8a77c43efc
Signed-off-by: Karol Latecki <karol.latecki@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/453652
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Reviewed-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Pawel Kaminski <pawelx.kaminski@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
If user calls rpc.py with no parameters, it currently
hangs, waiting for input. It should print help in this
case instead.
Signed-off-by: Jim Harris <james.r.harris@intel.com>
Change-Id: I5939999c57b8db0916267935d79ccc1a3201748b
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/453431
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com>
There are cases where srq can be a detriment. Add a flag to allow users
to disable srq even if they have a piece of hardware that supports it.
Change-Id: Ia3be8e8c8e8463964e6ff1c02b07afbf4c3cc8f7
Signed-off-by: Seth Howell <seth.howell@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/452271
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Just a couple minor clarifications.
Change-Id: I6c368d263296f742d5bfb0df431d3bf40c800c6c
Signed-off-by: Seth Howell <seth.howell@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/452270
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
iSCSI is currently being adapted to SPDK's new threading model,
and this parameter doesn't make sense anymore. Remove it for
now until something functionally equivalent is added later.
Change-Id: Ia0e2f5aa81b72d99467c5a900619fbeeb42b2069
Signed-off-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/452779
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
The product_name for raid bdevs was "Pooled Device" which was a legacy
naming convention that hadn't been cleaned up yet. This changes the
naming to be up to date with the current naming scheme.
Signed-off-by: Mike Carlin <mikefcarlin@protonmail.com>
Change-Id: I9092a2b793e48bb9ec0349087a31fdcde17ed9cd
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/452269
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Paul Luse <paul.e.luse@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Users can now pipe a large number of requests to
rpc.py, separated by newlines - each line will be
executed as if it was passed to rpc.py individually.
There is significant savings using this feature when
executing multiple requests through rpc.py. On my
system, a loop of 30 RPCs related to setting up
10 NVMf subsystems takes 5 seconds when executed
one at a time. With this new feature, it takes
less than 1 second.
Signed-off-by: Jim Harris <james.r.harris@intel.com>
Change-Id: Iec957ca67461af8e8c41aee47e1d113714b22d3d
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/452770
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
This makes no functional change to the script, but
it prepares for an upcoming change allowing callers
to pipe a newline delimited list of rpc calls.
Signed-off-by: Jim Harris <james.r.harris@intel.com>
Change-Id: I695ca61510f9edd336713e88d134e42c1d78a1b4
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/452769
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
We decided to name compress bdevs with COMP_ and then the name of
the underlying bdev so the RPC parm name was stale. Previously
hardcoded the path to PM for early dev so replaced name with pm_path.
Note that a sample create looks like this now:
rpc.py construct_compress_bdev -b NVMe0n1 -p ~/pm_files -d compress_isal
And that devs need to pay attention for the pathname they provide, its
easy to leave orphaned pm files around and they can get big.
Change-Id: Ifb5245c922461bbecec4bef266bdeb25e8b87f31
Signed-off-by: paul luse <paul.e.luse@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/452235
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
This script is not general purpose like gen_nvme.sh,
so move it to the test directory at least for now.
Signed-off-by: Jim Harris <james.r.harris@intel.com>
Change-Id: I22df9375a8fcd585884523f22dae8ba9354768d3
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/451785
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com>
This will allow us to test a greater number of connections without
having to add more subsystems when doing NVMe-oF testing.
Change-Id: I33203d6db79b30abb065f098c16840096478c5de
Signed-off-by: Seth Howell <seth.howell@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/451677
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Without this, spdkcli crashes when refreshing if any iSCSI
connections are established.
Signed-off-by: Jim Harris <james.r.harris@intel.com>
Change-Id: I82cd7a98e8c7d48e4730a7bd228ed483bdac28ef
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/451060
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
It seems that need to add help2man in pkgdep.sh , it was used in ISA-L module.
Change-Id: I9d69e2cba270b1802c333941160ca714b85c21d2
Signed-off-by: yidong0635 <dongx.yi@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/450562
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Add missing parameter numjobs. It is used in one of the cases.
Remove unnecessary arguments:
- cpumask: we do not want to restrict that
- percentile list: we do not want to restrict that, all
percentule buckets can be generated.
Change-Id: I6a4431af0defe92920f16d26091d67161e56dc5a
Signed-off-by: Karol Latecki <karol.latecki@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/450519
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
For future NVMeOF benchmarking scripts must support TCP layer.
This is a recent feature so also added support of using custom
built nvme-cli.
Example config file was updated with appropiate fields.
Rename rdma_ips to nic_ips, as NICs no longer need to be
RDMA-enabled for this test.
Change-Id: I368b48eca08a30b4221f198cb76134b8836dbba9
Signed-off-by: Karol Latecki <karol.latecki@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/449879
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Ziye Yang <ziye.yang@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Enhance RPC method start_nbd_disk to take nbd_device as
one optional parameter. If it is not assigned, automaticly
choose an available nbd device path from /dev/nbd0 to
/dev/nbdN.
For github issue #324:
https://github.com/spdk/spdk/issues/324
Change-Id: I72c064d8bd476df342f5aa0af4d6120eb021c7ed
Signed-off-by: Xiaodong Liu <xiaodong.liu@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/440453
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com>
User should know the request ID that was issued.
Change-Id: If1191f73b31ebe04f23a88a9ca31fa157474056b
Signed-off-by: Pawel Wodkowski <pawelx.wodkowski@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/449315
Reviewed-by: Karol Latecki <karol.latecki@intel.com>
Reviewed-by: Pawel Kaminski <pawelx.kaminski@intel.com>
Reviewed-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Client might wan't to handle error response on it's own. To keep
compatibility with legacy code we need to move exception rising to call
method.
Change-Id: I8a07e7556424e87ee10fa9332100a9a10abe05d8
Signed-off-by: Pawel Wodkowski <pawelx.wodkowski@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/449314
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
The changes I made to the doc directory in spdk.github.io got
overwritten.
Change-Id: I468c7eeb8c36ccd969909e179c216d5def812602
Signed-off-by: Seth Howell <seth.howell@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/449360
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Paweł Niedźwiecki <pawelx.niedzwiecki@intel.com>
Defer the initialization when cache bdev mentioned in the config doesn't
exist when the FTL bdev is being created.
Signed-off-by: Konrad Sztyber <konrad.sztyber@intel.com>
Change-Id: I084502ae38c9ae5e385e5566550ec3cb8b6f9d2e
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/448630
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Paul Luse <paul.e.luse@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Wojciech Malikowski <wojciech.malikowski@intel.com>
Reviewed-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Added means to configure libftl to use (optionally) another bdev as
persistent write buffer cache.
Signed-off-by: Konrad Sztyber <konrad.sztyber@intel.com>
Change-Id: I97028a681be168d9386eac8a226631ff772f803b
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/448629
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Wrong indent level caused results to be duplicated in final
output file if configuration file was used to run more than one
workload combination.
Change-Id: I0fadc10eba38898df648ec2da5fbd0440a3b9693
Signed-off-by: Karol Latecki <karol.latecki@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/449150
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Pawel Kaminski <pawelx.kaminski@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Just the starting point, base functions and structs.
Change-Id: I2ff2b672aa675a19b89e4449f1cc4aa664007f6f
Signed-off-by: Paul Luse <paul.e.luse@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/435747
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
When testing on VM using a 10G .img file is problematic
due to size - sometimes there is not enough space.
Decreasing the size should improve this issue.
Change-Id: I7be91aaa56a4e7f60cfdffc67f85ae8b3f42b650
Signed-off-by: yidong0635 <dongx.yi@intel.com>
Signed-off-by: Karol Latecki <karol.latecki@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/449167
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com>
Extend existing get_ocf_bdevs call to make it easier
to get information about attached cores.
Implementation is based adding additional optional argument "name"
to existing call. Based on "name" bdevs are filtered.
Backward compatability of RPC interface is preserved.
This patch also adds tests for the case when name is given.
Change-Id: I4300ebe37e936bc5cca8e066b5f09db462a87cf7
Signed-off-by: Vitaliy Mysak <vitaliy.mysak@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/444841
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
scripts/fio.py and test/nvmf/fio/nvmf_fio.py are almost exact
same script. This commit unifies two files into one.
Change-Id: If753baaeb9f92dad2cda27bb4bed78ade4827d0b
Signed-off-by: Karol Latecki <karol.latecki@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/448656
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Seth Howell <seth.howell5141@gmail.com>
Reviewed-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com>
Reviewed-by: Vitaliy Mysak <vitaliy.mysak@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Check if the UUID in the configuration is null (all zeroes) and treat it
as if no UUID has been supplied.
Signed-off-by: Konrad Sztyber <konrad.sztyber@intel.com>
Change-Id: Ic91c77591528a8aaa4cf5c0241e6bde51b3757f1
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/448628
Reviewed-by: Wojciech Malikowski <wojciech.malikowski@intel.com>
Reviewed-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
On non NUMA architectures the numa_node sysfs entry doesn't exist.
Check if it exists before reading to prevent an error causing 'status'
to fail.
Reviewed-by: Qingmin Liu <qingmin.liu@broadcom.com>
Tested-by: Jonathan Richardson <jonathan.richardson@broadcom.com>
Reviewed-by: Jonathan Richardson <jonathan.richardson@broadcom.com>
Reviewed-by: Scott Branden <scott.branden@broadcom.com>
Signed-off-by: Jonathan Richardson <jonathan.richardson@broadcom.com>
Change-Id: Iacf5b062a4f5db5e049d2cfcff7c991d4ac5d3c3
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/448576
Reviewed-by: Scott Branden <sbranden@gmail.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Qingmin Liu <calmarrow@gmail.com>
Reviewed-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
The python script for add_portal_group had required each portal is
an argument and portal list are made of remaining all arguments.
However this prevents adding new parameters to add_portal_group.
This patch changes portal list to be a single argument for python,
and each portal is separated by a whitespace in the argument.
Currently there will be very rare that a portal group has multiple
portals. Hence this change will not break any compatibility.
Updating CHANGELOG will be done together with other updates later.
Change-Id: I8c597a1194fff338afb371e6d24f9273122b753c
Signed-off-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/446379
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com>
For NVMe devices, in conjunction with the new batching options,
it can be advantageous to artificially delay between polling
for completions. Add an option to slow this rate down.
Change-Id: I0fc92709ff45ead0beb388dda60694bf1ed8b258
Signed-off-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/447716
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
The JSONRPCClient class now support the with statement. From now on the
__del__() method is changed to close() and user need to call it manually
at object disposal or use the 'with' Python statement.
Change-Id: I74afd93d411b9596ab8f9523c54a4a7523eec5e5
Signed-off-by: Pawel Wodkowski <pawelx.wodkowski@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/444686
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Pawel Kaminski <pawelx.kaminski@intel.com>
This will allow testing notifications code where user will most likely
issue many requests and socket buffereing might just squash them into
one packet.
Note that multiple requests are not send in batch mode.
Change-Id: Icfa4bfe21ff1268796bc41cf0443737f260b6040
Signed-off-by: Pawel Wodkowski <pawelx.wodkowski@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/436529
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Add extra long argument '--verbose <VERBOSE LEVEL>' to add more log
levels Default is error. Legacy'-v' parameter is translated into INFO
log level.
Some parts of code are logged using DEBUG level.
Change-Id: I2aaa6e2fbaf9b2101c6eeaec0cef6141636f135b
Signed-off-by: Pawel Wodkowski <pawelx.wodkowski@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/436528
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Switch to raw_decode in recv() function. This allow to decode JSON
objects one by one. Decoded part is removed from from receive bufer.
Change-Id: Id0d78a2ace85bcbb9cc8e30d72da6c1c2cad753c
Signed-off-by: Pawel Wodkowski <pawelx.wodkowski@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/435507
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Karol Latecki <karol.latecki@intel.com>
Reviewed-by: Pawel Kaminski <pawelx.kaminski@intel.com>
OpenSUSE releases (OpenSUSE Leap and Tumbleweed) now use
/etc/SUSE-brand than /etc/SuSE-release as SUSE identification.
According to this change, This commit intends to update
scripts/pkgdep so that it could install packages for OpenSUSE.
Tested on OpenSUSE Leap 15.0 and latest Tumblweed.
Change-Id: I878b6671753084ef718e1f7630a42520a72ea151
Signed-off-by: Zhu Lingshan <lingshan.zhu@intel.com>
Reviewed-on: https://review.gerrithub.io/c/spdk/spdk/+/446504
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
This RPC was deprecated a couple of releases ago.
bdev modules now each have their own RPC for deleting
bdevs. Due to how bdevs are created differently on
different modules, it is simply not possible to
have one delete_bdev RPC that would work for all bdev
types.
Signed-off-by: Jim Harris <james.r.harris@intel.com>
Change-Id: Ia46c95dce6e35f7557e8d41c41b8fea382924547
Reviewed-on: https://review.gerrithub.io/c/442615
Reviewed-by: Shuhei Matsumoto <shuhei.matsumoto.xt@hitachi.com>
Reviewed-by: Darek Stojaczyk <dariusz.stojaczyk@intel.com>