As per the NVMe specification, a host can identify two areas of guest
memory: one of which is used for the host-written doorbells, and one of
which contains event indexes. The host writes to the shadow doorbell
area, but also writes to the controller's BAR0 doorbell area if the
corresponding event index is crossed by the update. This avoids many
mmio exits in interrupt mode, where BAR0 doorbells are not directly
mapped into the guest VM, with greatly improved performance.
This isn't a useful feature in BAR0 doorbells are mapped into the VM, so
we explicitly disable support in that case.
NB: the Windows NVMe driver doesn't yet support this feature.
Although the specification says that the admin queues should also engage
in this behaviour, in practice, no VM does, so have to include some
hacks to account for this.
Co-authored-by: John Levon <john.levon@nutanix.com>
Signed-off-by: John Levon <john.levon@nutanix.com>
Change-Id: I0646b234d31fbbf9a6b85572042c6cdaf8366659
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/11492
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Community-CI: Mellanox Build Bot
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
The value of ack_timeout is calculated according to
the formula 2^(transport_ack_timeout) msec.
Signed-off-by: zhangduan <zhangd28@chinatelecom.cn>
Change-Id: I5a938635d70693ddd405fa5907555bb745b4df0f
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/12215
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Shuhei Matsumoto <smatsumoto@nvidia.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
This probe was removed from the bdev nvme module during
some recent refactoring.
Signed-off-by: Jim Harris <james.r.harris@intel.com>
Change-Id: I31508fb67651693e1e9c4a656e2e7111c14a8415
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/12002
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Monica Kenguva <monica.kenguva@intel.com>
Reviewed-by: Dong Yi <dongx.yi@intel.com>
Reviewed-by: Shuhei Matsumoto <smatsumoto@nvidia.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
After 7610bc38d, python modules are now located in the python/
directory. That patch also updated PYTHONPATH assignment in most of the
scripts, but one of the perf script and some docs/messages were missed.
Change-Id: Iff3588526f2a382e599f5734d38fc32c15a7bf56
Signed-off-by: Konrad Sztyber <konrad.sztyber@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/12223
Reviewed-by: Karol Latecki <karol.latecki@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Use "generic" Fedora34 from Roboxes, as we did for
all other Fedora Vagrant boxes.
Signed-off-by: Karol Latecki <karol.latecki@intel.com>
Change-Id: I208264c50a067b26c9ec5da2250f27881ba8431d
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/12227
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Pawel Piatek <pawelx.piatek@intel.com>
Fix pylint findings:
- R0201 Method could be a function
Signed-off-by: Pawel Piatek <pawelx.piatek@intel.com>
Change-Id: I1b9141b9ab150e20fdcd63510b484c6be514efb5
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/12137
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Karol Latecki <karol.latecki@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
This is done to make sure we don't miss more complex setups where
target devices are not mounted but still hold some valid data that
shouldn't be touched in any way.
Also, adjust function names so they clearly indicate what is being
checked.
Signed-off-by: Michal Berger <michallinuxstuff@gmail.com>
Change-Id: Ibb0f1f21de68009a2f8f1faf4595a07ae527da35
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/11111
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Mellanox Build Bot
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Up until now, importing an SPDK RPC python module was just a matter of
`import rpc`. It's fine until there's another module called `rpc`
installed on the system, in which case it's impossible to import both of
them. Therefore, to avoid this problem, all of the modules were moved
to a separate directory under the "spdk" namespace.
The decision to move to a location under a separate directory was
motivated by the fact that a directory called scripts/spdk would look
pretty confusing. Moreover, it should make it also easier to package
these scripts as a python package.
Other than moving the packages, all of the imports were updated to
reflect these changes. Files under python now use relative imports,
while those under scripts/ use the "spdk" namespace and have their
PYTHONPATH extended with python directory.
Signed-off-by: Konrad Sztyber <konrad.sztyber@intel.com>
Change-Id: Ib43dee73921d590a551dd83885e22870e72451cf
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/9692
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
The concat module can combine multiple underlying bdevs to a single
bdev. It is a special raid level. You can add a new bdev to the end of
the concat bdev, then the concat bdev size is increased, and it won't
change the layout of the exist data. This is the major difference
between concat and raid0. If you add a new underling device to raid0,
the whole data layout will be changed. So the concat bdev is extentable.
Change-Id: Ibbeeaf0606ff79b595320c597a5605ab9e4e13c4
Signed-off-by: Peng Yu <yupeng0921@gmail.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/11070
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
If a VMD device present, add message to communicate to the user to use next steps.
Allow for DRIVER_OVERRIDE="none" to just unbind the driver without binding it to any other.
Fixes#2423
Signed-off-by: Samir Raval <samir.raval@intel.com>
Change-Id: Ifef6ed50dd619ce7629eabf458edd54e6bb22fa4
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/12035
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Community-CI: Mellanox Build Bot
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Paul Luse <paul.e.luse@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Setting this optional parameter to true makes the
RPC completion wait until the attach for all
discovered NVM subsystems have completed.
This is especially useful for fio or bdevperf, to
ensure that all of the namespaces are actually
available before testing.
Signed-off-by: Jim Harris <james.r.harris@intel.com>
Change-Id: Icf04a122052f72e263a26b3c7582c81eac32a487
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/12044
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
'Content-Length' is not always available
specifically when using 'chunked' Transfer-Encoding
https://en.wikipedia.org/wiki/Chunked_transfer_encoding
This patch allows to handle chunked data transfer
and construct the request from peices.
The example of how to send chunked data:
> curl -k --user spdkuser:spdkpass -X POST -H "Content-Type: application/json" \
-H "Transfer-Encoding: chunked" \
-d '{"id": 1, "method": "bdev_get_bdevs"}' \
http://127.0.0.1:9009/
vs
> curl -k --user spdkuser:spdkpass -X POST -H "Content-Type: application/json" \
-d '{"id": 1, "method": "bdev_get_bdevs"}' \
http://127.0.0.1:9009/
Signed-off-by: Boris Glimcher <Boris.Glimcher@emc.com>
Change-Id: I6cf565d6639aa31898585f005d75785c43204552
Signed-off-by: Boris Glimcher <Boris.Glimcher@emc.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/12082
Reviewed-by: Pawel Piatek <pawelx.piatek@intel.com>
Reviewed-by: Paul Luse <paul.e.luse@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
This opption allows the bdev_get_bdevs RPC to block until a bdev with
specified name appears. It can be useful, when a bdev is created
asynchronously and the exact moment at which it appears is not known.
For instance, with a discovery service, a bdev is created when a
namespace on a remote NVMeoF target is added, but it's not possible to
specify when that happens exactly.
Signed-off-by: Konrad Sztyber <konrad.sztyber@intel.com>
Change-Id: I6c1f974fba445376ca9d45aac2639202547410cc
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/11960
Community-CI: Mellanox Build Bot
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Shuhei Matsumoto <smatsumoto@nvidia.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
These parameters will be used for any controller created
by the discovery service.
Signed-off-by: Jim Harris <james.r.harris@intel.com>
Change-Id: I221b791f38b9c5797ba084c647a98b82c102a121
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/11942
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Mellanox Build Bot
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Reviewed-by: Shuhei Matsumoto <smatsumoto@nvidia.com>
In vfio-user transport, whenever one IO is completed, it will trigger
an interrupt to guest machine. This cost quite some overhead. This patch
adds an adaptive irq feature to reduce interrupt overhead and boost
performance.
Signed-off-by: Rui Chang <rui.chang@arm.com>
Change-Id: I585be072231a934fa2e4fdf2439405de95151381
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/11840
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Community-CI: Mellanox Build Bot
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
With these we can write a simple bpftrace script to identify work being done,
and in particular what woke us up from sleeping.
Signed-off-by: John Levon <john.levon@nutanix.com>
Change-Id: I8997d847625ee4558092dbd753e6fc1b17beca92
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/9424
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Community-CI: Mellanox Build Bot
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
SPDK has settled on what the optimal DSA configuration is, so let's
always use it.
Change-Id: I24b9b717709d553789285198b1aa391f4d7f0445
Signed-off-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/11532
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Paul Luse <paul.e.luse@intel.com>
Make use of code implemented in previous patches in the series
to get and set dynamic scheduler values.
Modifiy app.py and rpc.py to accomodate new changes and allow
user to specify scheduler parameters in the RPC calls.
Change-Id: I6173aefbf1d774b91b80ee5bce67eea80a2ab23d
Signed-off-by: Krzysztof Karas <krzysztof.karas@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/11449
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Community-CI: Mellanox Build Bot
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Add three options for I/O error resiliency to spdk_nvme_bdev_opts.
Then the RPC bdev_nvme_set_options can configure these.
These can be overridden if these are given by the RPC bdev_nvme_attach_controller.
Change-Id: If3ee23aeef8b7585fe0fb5ec4695df5866fc1e74
Signed-off-by: Shuhei Matsumoto <smatsumoto@nvidia.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/11830
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
In case collect_driver() returns immediately due to missing modalias
attr, an empty $driver will be passed to check_for_driver() causing
grep inside to fail. Further false-positive then leads to call to
linux_bind_driver() as it's not able to locate proper paths for
given driver.
To avoid this, make sure collect_driver() always attempts to fallback
to a driver setup.sh supports for a target device.
Signed-off-by: Michal Berger <michallinuxstuff@gmail.com>
Change-Id: Id5631a731910f60b63c6afb3a412575bb69d784a
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/11747
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
The following patch will need it to expand the %{python3_sitelib} macros
when building the RPMs.
Signed-off-by: Konrad Sztyber <konrad.sztyber@intel.com>
Change-Id: I2782b228066fa0524d675c8d964217a7c9d11e36
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/11656
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Reviewed-by: Paul Luse <paul.e.luse@intel.com>
Now that users need to explicitly add a listener for the discovery
subsystem, make that a bit easier when using rpc.py. Instead of
having to type out nqn.2014-08.org.nvmexpress.discovery, allow
user to just specify 'discovery' as the NQN and rpc.py will
convert it to the discovery NQN before sending the RPC.
Signed-off-by: Jim Harris <james.r.harris@intel.com>
Change-Id: I4854d4f072f1758fdd6b37a4c3685e2a2d015caa
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/11540
Community-CI: Mellanox Build Bot
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Reviewed-by: Shuhei Matsumoto <smatsumoto@nvidia.com>
Signed-off-by: Karol Latecki <karol.latecki@intel.com>
Change-Id: I80e1fdb8b0a3b944ab6efdd21187cef07b685c29
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/11271
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
This was left out by the ea71df4f48.
Signed-off-by: Michal Berger <michallinuxstuff@gmail.com>
Change-Id: Ibd341eaa7e5a0b1a409a9efad081555728b7f880
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/10941
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Reviewed-by: Pawel Piatek <pawelx.piatek@intel.com>
Reviewed-by: Karol Latecki <karol.latecki@intel.com>
Reviewed-by: Dong Yi <dongx.yi@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Konrad Sztyber <konrad.sztyber@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
This parameter was ignored, and was a parameter to the
nvmf_set_config RPC.
For reference, this was deprecated in June 2020, commit
c37cf9fb.
Signed-off-by: Jim Harris <james.r.harris@intel.com>
Change-Id: I013f4d7cf874e7e26a8a1d299fdf9d8fa05da580
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/11544
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Community-CI: Mellanox Build Bot
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
This was a parameter on the nvmf_create_transport
RPC, and was replaced with max_io_qpairs_per_ctrlr to
reduce confusion on whether this number included the
admin queue or not.
nvmf_vhost test was using this deprecated parameter.
Change it to use -m (max_io_qpairs_per_ctrlr)
instead. '-p 4' would have been evaluated as 1 admin
queue + 3 I/O queues, but it's likely the intent
was for 4 I/O queues. This is a perfect example of
why this parameter was deprecated.
For reference, this was deprecated in June 2020,
commit 1551197db.
Signed-off-by: Jim Harris <james.r.harris@intel.com>
Change-Id: I4364fc0a76c9993b376932b6eea243d7cefca9cd
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/11543
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
rpc.py users can pipe RPC calls through stdin, which
reduces overhead compared to calling rpc.py
separately for each RPC.
It is common to put these RPC calls in a file, and
then pipe that file to rpc.py. To allow commenting
out RPC calls when doing debugging, have rpc.py
ignore any lines which begin with '#', allowing users
to comment out RPC calls (or even add comments
explaining the RPC calls) with a '#' character.
Signed-off-by: Jim Harris <james.r.harris@intel.com>
Change-Id: I8d9c6ac95dd5864c16e4d69ba80f81799068e808
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/11506
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Community-CI: Mellanox Build Bot
Reviewed-by: Dong Yi <dongx.yi@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Using time_based tasks with do_verify=1 and rw=write
results in verification not being run. Basically
writes consume all run time and there's no time
left for verify:
fio: verification read phase will never start
because write phase uses all of runtime
Using verify_backlog we ask fio to verify after every
N blocks written.
Signed-off-by: Karol Latecki <karol.latecki@intel.com>
Change-Id: I4c1571f4fad893e47cc5fea2ad6b4e2a7d8cc5ef
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/11376
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Reviewed-by: Pawel Piatek <pawelx.piatek@intel.com>
Reviewed-by: Konrad Sztyber <konrad.sztyber@intel.com>
Reviewed-by: Ben Walker <benjamin.walker@intel.com>
Provides RPCs for the qpair error injection APIs to bdev_nvme.
These RPCs are useful in testing NVMeoF/NVMe behavior for various
error scenarios in production.
Signed-off-by: Michael Haeuptle <michael.haeuptle@hpe.com>
Change-Id: I0db7995d7a712d4f8a60e643d564faa6908c3a55
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/10992
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Community-CI: Mellanox Build Bot
Reviewed-by: Konrad Sztyber <konrad.sztyber@intel.com>
Reviewed-by: Shuhei Matsumoto <smatsumoto@nvidia.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
It may take a long time to detect network transport error
when e.g. port is removed on remote target. This timeout
depends on 2 parameters - retry_count and ack_timeout.
bdev_nvme_set_options supports configuration of retry_count
but transport_ack_timeout is missed. Note: this parameter
is used by RDMA transport only.
Signed-off-by: Alexey Marchuk <alexeymar@mellanox.com>
Change-Id: I7c3090dc8e4078f64d444e2392a9e0a6ecdc31c0
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/11175
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Shuhei Matsumoto <smatsumoto@nvidia.com>
Reviewed-by: <tanl12@chinatelecom.cn>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Added preallocation option for raw NVMe disk images.
It matches qemu-img option for raw images.
By default raw images are created with "off" option,
resulting in increased size of the disk image as it is used.
Using "falloc" option preallocates the full size of the disk,
but does not write zeroes to it, compared to "full" option.
This will make sure that in CI, a device used during test
is never exhaused due to lack of host space.
Signed-off-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Change-Id: Ie1c30909dc87552a6d6c385d0ad80905ce68ff9d
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/11243
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Karol Latecki <karol.latecki@intel.com>
Reviewed-by: Konrad Sztyber <konrad.sztyber@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
SPDK test script can fail during any point of the
execution. To keep using the same devices
between test runs in CI, those devices have to
be cleaned between runs.
To select device for tests or to clean before tests,
the partition table and lack of mount points is used.
SPDK GPT partitions were always considered not in use.
Meanwhile Linux GPT were not, even if lacking a mount
point.
Some of the SPDK tests create Linux GPT partitions,
which might remain after a test run.
Linux GPT partitions created during tests now contain
"SPDK_TEST" as part of their partition name.
This allows marking such block devices as 'not in use',
to be cleaned and used in further SPDK test.
fixes#2345
Signed-off-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Change-Id: I0098776239da9b0c5dcc748625485284e4863525
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/11220
Reviewed-by: Michal Berger <michallinuxstuff@gmail.com>
Reviewed-by: Dong Yi <dongx.yi@intel.com>
Reviewed-by: Pawel Piatek <pawelx.piatek@intel.com>
Reviewed-by: Konrad Sztyber <konrad.sztyber@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Signed-off-by: Michal Berger <michallinuxstuff@gmail.com>
Change-Id: I5e1cdb75b8b4421b2a38fe315f75e11d8ea5de23
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/11110
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Dong Yi <dongx.yi@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Add configuration options to enable using IDXD
for data digest during NVMe-oF performance testing.
Change-Id: I54d443c35c67e0331e3d6ec4aecb577fc7f544c7
Signed-off-by: John Kariuki <John.K.Kariuki@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/10282
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Karol Latecki <karol.latecki@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Add more dtrace probes to help with identifying issues
in production.
Change-Id: I8fb621a15c5e33ae94d75b4fc31135e2635dcfce
Signed-off-by: Krzysztof Karas <krzysztof.karas@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/10561
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Signed-off-by: Maciej Wawryk <maciejx.wawryk@intel.com>
Change-Id: I72fc8cb42f57d3272a08a6cefc58b2fa5eb26419
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/11094
Reviewed-by: Konrad Sztyber <konrad.sztyber@intel.com>
Reviewed-by: Karol Latecki <karol.latecki@intel.com>
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
As described in Python documentation:
It is not guaranteed that __del__() methods are called for
objects that still exist when the interpreter exits.
Because of that class instance objects were not always destroyed
after tests.
Change-Id: I10f05a480cde37d274d6475efdf47d094cab7cb9
Signed-off-by: Karol Latecki <karol.latecki@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/11136
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Reviewed-by: Konrad Sztyber <konrad.sztyber@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
If ctrlr_loss_timeout_sec is set to -1, reconnect is tried repeatedly
indefinitely, and I/Os continue to be queued.
This patch adds another option fast_io_fail_timeout_sec, a flag
fast_io_fail_timedout to nvme_ctrlr.
If the time fast_io_fail_timeout_sec passed after starting reset,
set fast_io_fail_timedout to true not to use the path for I/O submission.
fast_io_fail_timeout_sec is initialized to zero as same as
ctrlr_loss_timeout_sec and reconnect_delay_sec.
The name of the parameter follows the famous DM-multipath, its fast_io_fail_tmo.
Change-Id: Ib870cf8e2fd29300c47f1df69617776f4e67bd8c
Signed-off-by: Shuhei Matsumoto <smatsumoto@nvidia.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/10301
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Previously reconnect retry was not controlled and was repeated indefinitely.
This patch adds two options, ctrlr_loss_timeout_sec and reconnect_delay_sec,
to nvme_ctrlr and add reset_start_tsc, reconnect_is_delayed, and
reconnect_delay_timer to nvme_ctrlr to control reconnect retry.
Both of ctrlr_loss_timeout_sec and reconnect_delay_sec are initialized to
zero. This means reconnect is not throttled as we did before this patch.
A few more changes are added.
Change nvme_io_path_is_failed() to return false if reset is throttled
even if nvme_ctrlr is reseting or is to be reconnected.
spdk_nvme_ctrlr_reconnect_poll_async() may continue returning -EAGAIN
infinitely. To check out such exceptional case, use ctrlr_loss_timeout_sec.
Not only ctrlr reset but also non-multipath ctrlr failover is controlled.
So we need to include path failover into ctrlr reconnect.
When the active path is removed and switched to one of the alternative paths,
if ctrlr reconnect is scheduled, connecting to the alternative path is left
to the scheduled reconnect.
If reset or reconnect ctrlr is failed and the retry is scheduled,
switch the active path to one of alternative paths.
Restore unit test cases removed in the previous patches.
Change-Id: Idec636c4eced39eb47ff4ef6fde72d6fd9fe4f85
Signed-off-by: Shuhei Matsumoto <smatsumoto@nvidia.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/10128
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Community-CI: Mellanox Build Bot
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Monica Kenguva <monica.kenguva@intel.com>
In project practice, config_file and key_file are often used to connect
to a rados cluster, config_file includes "mon_host" and other rados
configurations like "rbd_cache", and key_file includes the secret key
and the access authority to each pool for current user. This patch adds
key_file option, user can specify config_file and key_file or only config_param
to connect rados cluster. This will make it much more flexible for users with
his/her convenience.
Signed-off-by: Tan Long <tanl12@chinatelecom.cn>
Change-Id: I6b49aad70b578bdeb3ac8ea9ca0fcbd931582025
Signed-off-by: Tan Long <tanl12@chinatelecom.cn>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/10485
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Community-CI: Mellanox Build Bot
Reviewed-by: GangCao <gang.cao@intel.com>
Reviewed-by: Changpeng Liu <changpeng.liu@intel.com>
Reviewed-by: Xiaodong Liu <xiaodong.liu@intel.com>
Reviewed-by: Aleksey Marchuk <alexeymar@mellanox.com>
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Add support to enable individual traces through rpc commands
and modify jsonrpc.md to describe the changes.
Change-Id: I3664fc28f1c25a76eade4cff0a0ab1870172f8de
Signed-off-by: Krzysztof Karas <krzysztof.karas@intel.com>
Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/10518
Tested-by: SPDK CI Jenkins <sys_sgci@intel.com>
Community-CI: Broadcom CI <spdk-ci.pdl@broadcom.com>
Reviewed-by: Konrad Sztyber <konrad.sztyber@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>