Postivive test case for testing lvol tasting feature. Change-Id: Ifa8b87978e40a719ca59603cfd41a8fd1b22c6f9 Signed-off-by: Lukasz Galka <lukaszx.galka@intel.com> Signed-off-by: Karol Latecki <karol.latecki@intel.com> Reviewed-on: https://review.gerrithub.io/382687 Tested-by: SPDK Automated Test System <sys_sgsw@intel.com> Reviewed-by: Maciej Szwed <maciej.szwed@intel.com> Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com> Reviewed-by: Daniel Verkamp <daniel.verkamp@intel.com>
This commit is contained in:
parent
511adde02f
commit
d88fa70e58
@ -454,3 +454,63 @@ Expected result:
|
||||
- calls successful, return code = 0
|
||||
- get_bdevs: no change
|
||||
- no other operation fails
|
||||
|
||||
# Lvol tasting test plan
|
||||
|
||||
## Objective
|
||||
The purpose of these tests is to verify the introduced lvol store and lvols parameters saving
|
||||
on persistent memory and loading it from saved data on app start in SPDK.
|
||||
|
||||
## Methodology
|
||||
Configuration test cases use vhost app.
|
||||
All tests are performed using NVMe device backends.
|
||||
All management is done using RPC calls, including logical volumes management.
|
||||
|
||||
Tests will be executed as scenarios - A set of test steps in which checks get_lvol_stores response
|
||||
(rpc command) after again start vhost app
|
||||
|
||||
## Tests
|
||||
|
||||
### tasting_positive
|
||||
|
||||
#### TEST CASE 1
|
||||
Positive test for tasting a multi lvol bdev configuration.
|
||||
Create a lvol store with some lvol bdevs on NVMe drive and restart vhost app.
|
||||
After restarting configuration should be automatically loaded and should be exactly
|
||||
the same as before restarting.
|
||||
Check that running configuration can be modified after restarting and tasting.
|
||||
Steps:
|
||||
- run vhost app with NVMe bdev
|
||||
- construct lvol store on NVMe bdev
|
||||
- using get_lvol_stores command verify lvol store was correctly created
|
||||
- construct five lvol bdevs on previously created lvol store;
|
||||
each lvol bdev size is approximately equal to 10% of total lvol store size
|
||||
(approximately because of the lvol metadata which consumes some of the space)
|
||||
- using get_bdevs command verify lvol bdevs were correctly created
|
||||
- shutdown vhost application by sending SIGTERM signal
|
||||
- start vhost application with the same NVMe bdev as in the first step
|
||||
- using get_lvol_stores command verify that previously created lvol strore
|
||||
was correctly discovered and loaded by tasting feature (including UUID's)
|
||||
- using get_bdevs command verify that previously created lvol bdevs were
|
||||
correctly discovered and loaded by tasting feature (including UUID's)
|
||||
- verify if configuration can be modified after tasting:
|
||||
construct five more lvol bdevs to fill up loaded lvol store,
|
||||
delete all existing lvol bdevs,
|
||||
destroy existing lvol store,
|
||||
verify removal results using get_lvol_stores and get_bdevs commands
|
||||
- re-create initial configuration by repeating steps 2-5:
|
||||
create lvol store on NVMe bdev, create four lvol bdevs on lvol store and
|
||||
verify all configuration call results
|
||||
- clean running configuration:
|
||||
delete all lvol bdevs,
|
||||
destroy lvol store
|
||||
verify removal results using get_lvol_stores and get_bdevs commands
|
||||
|
||||
Expected results:
|
||||
- configuration is successfully tasted and loaded after restarting vhost
|
||||
- lvol store attributes (UUID, total size, cluster size, etc.) remain the same after
|
||||
loading existing configuration
|
||||
- lvol bdev attributes (UUID, size, etc.) remain the same after
|
||||
loading existing configuration
|
||||
- all RPC configuration calls successful, return code = 0
|
||||
- no other operation fails
|
||||
|