event: Remove duplicated code when installing signal handlers
Change-Id: I8cb413cd18b738438f1b1b3e00a438e1323e8b1f Signed-off-by: Ben Walker <benjamin.walker@intel.com> Reviewed-on: https://review.gerrithub.io/372170 Tested-by: SPDK Automated Test System <sys_sgsw@intel.com> Reviewed-by: Daniel Verkamp <daniel.verkamp@intel.com> Reviewed-by: Jim Harris <james.r.harris@intel.com>
This commit is contained in:
parent
0fb41bb11f
commit
c549377169
@ -291,10 +291,10 @@ spdk_app_start(struct spdk_app_opts *opts, spdk_event_fn start_fn,
|
||||
}
|
||||
|
||||
sigemptyset(&sigmask);
|
||||
|
||||
memset(&sigact, 0, sizeof(sigact));
|
||||
sigact.sa_handler = SIG_IGN;
|
||||
sigemptyset(&sigact.sa_mask);
|
||||
|
||||
sigact.sa_handler = SIG_IGN;
|
||||
rc = sigaction(SIGPIPE, &sigact, NULL);
|
||||
if (rc < 0) {
|
||||
SPDK_ERRLOG("sigaction(SIGPIPE) failed\n");
|
||||
@ -302,8 +302,9 @@ spdk_app_start(struct spdk_app_opts *opts, spdk_event_fn start_fn,
|
||||
exit(EXIT_FAILURE);
|
||||
}
|
||||
|
||||
/* Install the same handler for SIGINT and SIGTERM */
|
||||
sigact.sa_handler = __shutdown_signal;
|
||||
sigemptyset(&sigact.sa_mask);
|
||||
|
||||
rc = sigaction(SIGINT, &sigact, NULL);
|
||||
if (rc < 0) {
|
||||
SPDK_ERRLOG("sigaction(SIGINT) failed\n");
|
||||
@ -312,8 +313,6 @@ spdk_app_start(struct spdk_app_opts *opts, spdk_event_fn start_fn,
|
||||
}
|
||||
sigaddset(&sigmask, SIGINT);
|
||||
|
||||
sigact.sa_handler = __shutdown_signal;
|
||||
sigemptyset(&sigact.sa_mask);
|
||||
rc = sigaction(SIGTERM, &sigact, NULL);
|
||||
if (rc < 0) {
|
||||
SPDK_ERRLOG("sigaction(SIGTERM) failed\n");
|
||||
@ -324,7 +323,6 @@ spdk_app_start(struct spdk_app_opts *opts, spdk_event_fn start_fn,
|
||||
|
||||
if (opts->usr1_handler != NULL) {
|
||||
sigact.sa_handler = opts->usr1_handler;
|
||||
sigemptyset(&sigact.sa_mask);
|
||||
rc = sigaction(SIGUSR1, &sigact, NULL);
|
||||
if (rc < 0) {
|
||||
SPDK_ERRLOG("sigaction(SIGUSR1) failed\n");
|
||||
|
Loading…