test/nvmf_vfio_user: add one more device to the target
Previously we only tested one device with vfio-user target, now add one more device to the test script. Change-Id: I6923a313b23f93e6fdc3f25baa060b9af43ba7f7 Signed-off-by: Changpeng Liu <changpeng.liu@intel.com> Reviewed-on: https://review.spdk.io/gerrit/c/spdk/spdk/+/6228 Tested-by: SPDK CI Jenkins <sys_sgci@intel.com> Community-CI: Mellanox Build Bot Reviewed-by: Ben Walker <benjamin.walker@intel.com> Reviewed-by: <dongx.yi@intel.com> Reviewed-by: Jim Harris <james.r.harris@intel.com>
This commit is contained in:
parent
0f30fea99b
commit
a3b56e7f4d
@ -5,8 +5,9 @@ rootdir=$(readlink -f $testdir/../../..)
|
||||
source $rootdir/test/common/autotest_common.sh
|
||||
source $rootdir/test/nvmf/common.sh
|
||||
|
||||
MALLOC_BDEV_SIZE=512
|
||||
MALLOC_BDEV_SIZE=64
|
||||
MALLOC_BLOCK_SIZE=512
|
||||
NUM_DEVICES=2
|
||||
|
||||
rpc_py="$rootdir/scripts/rpc.py"
|
||||
|
||||
@ -15,11 +16,6 @@ export TEST_TRANSPORT=VFIOUSER
|
||||
rm -rf /var/run/muser
|
||||
rm -rf /dev/shm/muser
|
||||
|
||||
mkdir -p /var/run/muser
|
||||
mkdir -p /var/run/muser/iommu_group
|
||||
mkdir -p /var/run/muser/domain/muser0/8
|
||||
mkdir -p /dev/shm/muser/muser0
|
||||
|
||||
# Start the target
|
||||
"${NVMF_APP[@]}" -m 0x1 &
|
||||
nvmfpid=$!
|
||||
@ -32,23 +28,33 @@ sleep 1
|
||||
|
||||
$rpc_py nvmf_create_transport -t VFIOUSER
|
||||
|
||||
$rpc_py bdev_malloc_create $MALLOC_BDEV_SIZE $MALLOC_BLOCK_SIZE -b Malloc0
|
||||
$rpc_py nvmf_create_subsystem nqn.2019-07.io.spdk:cnode0 -a -s SPDK0
|
||||
$rpc_py nvmf_subsystem_add_ns nqn.2019-07.io.spdk:cnode0 Malloc0
|
||||
$rpc_py nvmf_subsystem_add_listener nqn.2019-07.io.spdk:cnode0 -t VFIOUSER -a "/var/run/muser/domain/muser0/8" -s 0
|
||||
mkdir -p /var/run/muser
|
||||
mkdir -p /var/run/muser/iommu_group
|
||||
|
||||
ln -s /var/run/muser/domain/muser0/8 /var/run/muser/domain/muser0/8/iommu_group
|
||||
ln -s /var/run/muser/domain/muser0/8 /var/run/muser/iommu_group/8
|
||||
ln -s /var/run/muser/domain/muser0/8/bar0 /dev/shm/muser/muser0/bar0
|
||||
for i in $(seq 1 $NUM_DEVICES); do
|
||||
mkdir -p /var/run/muser/domain/muser$i/$i
|
||||
mkdir -p /dev/shm/muser/muser$i
|
||||
|
||||
$SPDK_EXAMPLE_DIR/identify -r 'trtype:VFIOUSER traddr:/var/run/muser/domain/muser0/8' -g -L nvme -L nvme_vfio -L vfio_pci
|
||||
sleep 1
|
||||
$SPDK_EXAMPLE_DIR/perf -r 'trtype:VFIOUSER traddr:/var/run/muser/domain/muser0/8' -s 256 -g -q 128 -o 4096 -w read -t 10 -c 0x2
|
||||
sleep 1
|
||||
$SPDK_EXAMPLE_DIR/perf -r 'trtype:VFIOUSER traddr:/var/run/muser/domain/muser0/8' -s 256 -g -q 128 -o 4096 -w write -t 10 -c 0x2
|
||||
sleep 1
|
||||
$SPDK_EXAMPLE_DIR/reconnect -r 'trtype:VFIOUSER traddr:/var/run/muser/domain/muser0/8' -g -q 32 -o 4096 -w randrw -M 50 -t 10 -c 0xE
|
||||
sleep 1
|
||||
$rpc_py bdev_malloc_create $MALLOC_BDEV_SIZE $MALLOC_BLOCK_SIZE -b Malloc$i
|
||||
$rpc_py nvmf_create_subsystem nqn.2019-07.io.spdk:cnode$i -a -s SPDK$i
|
||||
$rpc_py nvmf_subsystem_add_ns nqn.2019-07.io.spdk:cnode$i Malloc$i
|
||||
$rpc_py nvmf_subsystem_add_listener nqn.2019-07.io.spdk:cnode$i -t VFIOUSER -a "/var/run/muser/domain/muser$i/$i" -s 0
|
||||
|
||||
ln -s /var/run/muser/domain/muser$i/$i /var/run/muser/domain/muser$i/$i/iommu_group
|
||||
ln -s /var/run/muser/domain/muser$i/$i /var/run/muser/iommu_group/$i
|
||||
ln -s /var/run/muser/domain/muser$i/$i/bar0 /dev/shm/muser/muser$i/bar0
|
||||
done
|
||||
|
||||
for i in $(seq 1 $NUM_DEVICES); do
|
||||
$SPDK_EXAMPLE_DIR/identify -r "trtype:VFIOUSER traddr:/var/run/muser/domain/muser$i/$i" -g -L nvme -L nvme_vfio -L vfio_pci
|
||||
sleep 1
|
||||
$SPDK_EXAMPLE_DIR/perf -r "trtype:VFIOUSER traddr:/var/run/muser/domain/muser$i/$i" -s 256 -g -q 128 -o 4096 -w read -t 5 -c 0x2
|
||||
sleep 1
|
||||
$SPDK_EXAMPLE_DIR/perf -r "trtype:VFIOUSER traddr:/var/run/muser/domain/muser$i/$i" -s 256 -g -q 128 -o 4096 -w write -t 5 -c 0x2
|
||||
sleep 1
|
||||
$SPDK_EXAMPLE_DIR/reconnect -r "trtype:VFIOUSER traddr:/var/run/muser/domain/muser$i/$i" -g -q 32 -o 4096 -w randrw -M 50 -t 5 -c 0xE
|
||||
sleep 1
|
||||
done
|
||||
|
||||
killprocess $nvmfpid
|
||||
|
||||
|
Loading…
Reference in New Issue