nvmf: create a common script file for nvmf automation test
Put the common funcs in test/nvmf/common.sh to reduce duplicated code Change-Id: I1c72f6fb22d092dafb7fb134b8bb3780b5525e48 Signed-off-by: Ziye Yang <ziye.yang@intel.com> Signed-off-by: Gang Cao <gang.cao@intel.com>
This commit is contained in:
parent
f7ccfc6160
commit
34731b0b17
115
test/nvmf/common.sh
Executable file
115
test/nvmf/common.sh
Executable file
@ -0,0 +1,115 @@
|
|||||||
|
#!/usr/bin/env bash
|
||||||
|
|
||||||
|
NVMF_PORT=7174
|
||||||
|
NVMF_IP_PREFIX="192.168.100."
|
||||||
|
NVMF_IP_LEAST_ADDR=8
|
||||||
|
NVMF_FIRST_TARGET_IP=$NVMF_IP_PREFIX$NVMF_IP_LEAST_ADDR
|
||||||
|
|
||||||
|
nvmf_nic_bdfs=""
|
||||||
|
|
||||||
|
function load_ib_rdma_modules()
|
||||||
|
{
|
||||||
|
if [ `uname` != Linux ]; then
|
||||||
|
exit 0
|
||||||
|
fi
|
||||||
|
|
||||||
|
modprobe ib_addr ib_mad ib_sa || true # part of core since 4.7
|
||||||
|
modprobe ib_cm
|
||||||
|
modprobe ib_core
|
||||||
|
modprobe ib_ucm
|
||||||
|
modprobe ib_umad
|
||||||
|
modprobe ib_uverbs
|
||||||
|
modprobe iw_cm
|
||||||
|
modprobe rdma_cm
|
||||||
|
modprobe rdma_ucm
|
||||||
|
}
|
||||||
|
|
||||||
|
function detect_mellanox_nics()
|
||||||
|
{
|
||||||
|
nvmf_nic_bdfs=`lspci | grep Ethernet | grep Mellanox | awk -F ' ' '{print "0000:"$1}'`
|
||||||
|
mlx_core_driver="mlx4_core"
|
||||||
|
mlx_ib_driver="mlx4_ib"
|
||||||
|
mlx_en_driver="mlx4_en"
|
||||||
|
|
||||||
|
if [ -z "$nvmf_nic_bdfs" ]; then
|
||||||
|
exit 0
|
||||||
|
fi
|
||||||
|
|
||||||
|
# for nvmf target loopback test, suppose we only have one type of card.
|
||||||
|
for nvmf_nic_bdf in $nvmf_nic_bdfs
|
||||||
|
do
|
||||||
|
result=`find /sys -name $nvmf_nic_bdf | grep driver | awk -F / '{ print $6 }'`
|
||||||
|
if [ "$result" == "mlx5_core" ]; then
|
||||||
|
mlx_core_driver="mlx5_core"
|
||||||
|
mlx_ib_driver="mlx5_ib"
|
||||||
|
mlx_en_driver=""
|
||||||
|
fi
|
||||||
|
break;
|
||||||
|
done
|
||||||
|
|
||||||
|
# Uninstall/install driver to make a clean test environment
|
||||||
|
if lsmod | grep -q $mlx_ib_driver; then
|
||||||
|
rmmod $mlx_ib_driver
|
||||||
|
fi
|
||||||
|
|
||||||
|
if [ -n "$mlx_en_driver" ]; then
|
||||||
|
if lsmod | grep -q $mlx_en_driver; then
|
||||||
|
rmmod $mlx_en_driver
|
||||||
|
fi
|
||||||
|
fi
|
||||||
|
|
||||||
|
if lsmod | grep -q $mlx_core_driver; then
|
||||||
|
rmmod $mlx_core_driver
|
||||||
|
fi
|
||||||
|
|
||||||
|
modprobe $mlx_core_driver
|
||||||
|
modprobe $mlx_ib_driver
|
||||||
|
if [ -n "$mlx_en_driver" ]; then
|
||||||
|
modprobe $mlx_en_driver
|
||||||
|
fi
|
||||||
|
|
||||||
|
trap - SIGINT SIGTERM EXIT
|
||||||
|
}
|
||||||
|
|
||||||
|
function detect_rdma_nics()
|
||||||
|
{
|
||||||
|
# could be add other nics, so wrap it
|
||||||
|
detect_mellanox_nics
|
||||||
|
}
|
||||||
|
|
||||||
|
function allocate_nic_ips()
|
||||||
|
{
|
||||||
|
LEAST_ADDR=$NVMF_IP_LEAST_ADDR
|
||||||
|
for bdf in $1; do
|
||||||
|
dir=`find /sys -name $bdf | grep "/sys/devices"`
|
||||||
|
if [ -e $dir ]; then
|
||||||
|
if [ -e $dir"/net" ]; then
|
||||||
|
nic_name=`ls $dir"/net"`
|
||||||
|
# just get the first nic
|
||||||
|
nic_name=`echo $nic_name | awk '{ print $1; }'`
|
||||||
|
ifconfig $nic_name $NVMF_IP_PREFIX$LEAST_ADDR netmask 255.255.255.0 up
|
||||||
|
LEAST_ADDR=$[$LEAST_ADDR + 1]
|
||||||
|
fi
|
||||||
|
fi
|
||||||
|
done
|
||||||
|
# check whether the IP is configured
|
||||||
|
result=`ifconfig | grep $NVMF_IP_PREFIX`
|
||||||
|
if [ -z "$result" ]; then
|
||||||
|
echo "no NIC for nvmf test"
|
||||||
|
exit 0
|
||||||
|
fi
|
||||||
|
}
|
||||||
|
|
||||||
|
function nvmfcleanup()
|
||||||
|
{
|
||||||
|
rmmod nvme-rdma
|
||||||
|
rmmod nvme || true
|
||||||
|
}
|
||||||
|
|
||||||
|
function rdma_device_init()
|
||||||
|
{
|
||||||
|
load_ib_rdma_modules
|
||||||
|
detect_rdma_nics
|
||||||
|
allocate_nic_ips $nvmf_nic_bdfs
|
||||||
|
}
|
||||||
|
|
@ -3,108 +3,7 @@
|
|||||||
testdir=$(readlink -f $(dirname $0))
|
testdir=$(readlink -f $(dirname $0))
|
||||||
rootdir=$testdir/../../..
|
rootdir=$testdir/../../..
|
||||||
source $rootdir/scripts/autotest_common.sh
|
source $rootdir/scripts/autotest_common.sh
|
||||||
|
source $rootdir/test/nvmf/common.sh
|
||||||
NVMF_PORT=7174
|
|
||||||
NVMF_IP_PREFIX="192.168.100."
|
|
||||||
NVMF_IP_LEAST_ADDR=8
|
|
||||||
NVMF_FIRST_TARGET_IP=$NVMF_IP_PREFIX$NVMF_IP_LEAST_ADDR
|
|
||||||
|
|
||||||
nvmf_nic_bdfs=""
|
|
||||||
|
|
||||||
function load_ib_rdma_modules()
|
|
||||||
{
|
|
||||||
if [ `uname` != Linux ]; then
|
|
||||||
exit 0
|
|
||||||
fi
|
|
||||||
|
|
||||||
modprobe ib_addr ib_mad ib_sa || true # part of core since 4.7
|
|
||||||
modprobe ib_cm
|
|
||||||
modprobe ib_core
|
|
||||||
modprobe ib_ucm
|
|
||||||
modprobe ib_umad
|
|
||||||
modprobe ib_uverbs
|
|
||||||
modprobe iw_cm
|
|
||||||
modprobe rdma_cm
|
|
||||||
modprobe rdma_ucm
|
|
||||||
}
|
|
||||||
|
|
||||||
function detect_mellanox_nics()
|
|
||||||
{
|
|
||||||
nvmf_nic_bdfs=`lspci | grep Ethernet | grep Mellanox | awk -F ' ' '{print "0000:"$1}'`
|
|
||||||
mlx_core_driver="mlx4_core"
|
|
||||||
mlx_ib_driver="mlx4_ib"
|
|
||||||
mlx_en_driver="mlx4_en"
|
|
||||||
|
|
||||||
if [ -z "$nvmf_nic_bdfs" ]; then
|
|
||||||
exit 0
|
|
||||||
fi
|
|
||||||
|
|
||||||
# for nvmf target loopback test, suppose we only have one type of card.
|
|
||||||
for nvmf_nic_bdf in $nvmf_nic_bdfs
|
|
||||||
do
|
|
||||||
result=`find /sys -name $nvmf_nic_bdf | grep driver | awk -F / '{ print $6 }'`
|
|
||||||
if [ "$result" == "mlx5_core" ]; then
|
|
||||||
mlx_core_driver="mlx5_core"
|
|
||||||
mlx_ib_driver="mlx5_ib"
|
|
||||||
mlx_en_driver=""
|
|
||||||
fi
|
|
||||||
break;
|
|
||||||
done
|
|
||||||
|
|
||||||
# Uninstall/install driver to make a clean test environment
|
|
||||||
if lsmod | grep -q $mlx_ib_driver; then
|
|
||||||
rmmod $mlx_ib_driver
|
|
||||||
fi
|
|
||||||
|
|
||||||
if [ -n "$mlx_en_driver" ]; then
|
|
||||||
if lsmod | grep -q $mlx_en_driver; then
|
|
||||||
rmmod $mlx_en_driver
|
|
||||||
fi
|
|
||||||
fi
|
|
||||||
|
|
||||||
if lsmod | grep -q $mlx_core_driver; then
|
|
||||||
rmmod $mlx_core_driver
|
|
||||||
fi
|
|
||||||
|
|
||||||
modprobe $mlx_core_driver
|
|
||||||
modprobe $mlx_ib_driver
|
|
||||||
if [ -n "$mlx_en_driver" ]; then
|
|
||||||
modprobe $mlx_en_driver
|
|
||||||
fi
|
|
||||||
|
|
||||||
trap - SIGINT SIGTERM EXIT
|
|
||||||
}
|
|
||||||
|
|
||||||
function detect_rdma_nics()
|
|
||||||
{
|
|
||||||
detect_mellanox_nics
|
|
||||||
}
|
|
||||||
|
|
||||||
function allocate_nic_ips()
|
|
||||||
{
|
|
||||||
LEAST_ADDR=$NVMF_IP_LEAST_ADDR
|
|
||||||
for bdf in $1; do
|
|
||||||
dir=`find /sys -name $bdf | grep "/sys/devices"`
|
|
||||||
if [ -e $dir ]; then
|
|
||||||
if [ -e $dir"/net" ]; then
|
|
||||||
nic_name=`ls $dir"/net"`
|
|
||||||
echo $nic_name
|
|
||||||
ifconfig $nic_name $NVMF_IP_PREFIX$LEAST_ADDR netmask 255.255.255.0 up
|
|
||||||
LEAST_ADDR=$[$LEAST_ADDR + 1]
|
|
||||||
fi
|
|
||||||
fi
|
|
||||||
done
|
|
||||||
# check whether the IP is configured
|
|
||||||
result=`ifconfig | grep $NVMF_IP_PREFIX`
|
|
||||||
if [ -z "$result" ]; then
|
|
||||||
echo "no NIC for nvmf test"
|
|
||||||
exit 0
|
|
||||||
fi
|
|
||||||
}
|
|
||||||
|
|
||||||
function nvmfcleanup() {
|
|
||||||
rmmod nvme-rdma
|
|
||||||
}
|
|
||||||
|
|
||||||
function filesystem_test()
|
function filesystem_test()
|
||||||
{
|
{
|
||||||
@ -132,9 +31,7 @@ function filesystem_test()
|
|||||||
done
|
done
|
||||||
}
|
}
|
||||||
|
|
||||||
load_ib_rdma_modules
|
rdma_device_init
|
||||||
detect_rdma_nics
|
|
||||||
allocate_nic_ips $nvmf_nic_bdfs
|
|
||||||
|
|
||||||
timing_enter fs_test
|
timing_enter fs_test
|
||||||
|
|
||||||
|
@ -3,112 +3,9 @@
|
|||||||
testdir=$(readlink -f $(dirname $0))
|
testdir=$(readlink -f $(dirname $0))
|
||||||
rootdir=$testdir/../../..
|
rootdir=$testdir/../../..
|
||||||
source $rootdir/scripts/autotest_common.sh
|
source $rootdir/scripts/autotest_common.sh
|
||||||
|
source $rootdir/test/nvmf/common.sh
|
||||||
|
|
||||||
NVMF_PORT=7174
|
rdma_device_init
|
||||||
NVMF_IP_PREFIX="192.168.100."
|
|
||||||
NVMF_IP_LEAST_ADDR=8
|
|
||||||
NVMF_FIRST_TARGET_IP=$NVMF_IP_PREFIX$NVMF_IP_LEAST_ADDR
|
|
||||||
|
|
||||||
nvmf_nic_bdfs=""
|
|
||||||
|
|
||||||
function load_ib_rdma_modules()
|
|
||||||
{
|
|
||||||
if [ `uname` != Linux ]; then
|
|
||||||
exit 0
|
|
||||||
fi
|
|
||||||
|
|
||||||
modprobe ib_addr ib_mad ib_sa || true # part of core since 4.7
|
|
||||||
modprobe ib_cm
|
|
||||||
modprobe ib_core
|
|
||||||
modprobe ib_ucm
|
|
||||||
modprobe ib_umad
|
|
||||||
modprobe ib_uverbs
|
|
||||||
modprobe iw_cm
|
|
||||||
modprobe rdma_cm
|
|
||||||
modprobe rdma_ucm
|
|
||||||
}
|
|
||||||
|
|
||||||
function detect_mellanox_nics()
|
|
||||||
{
|
|
||||||
nvmf_nic_bdfs=`lspci | grep Ethernet | grep Mellanox | awk -F ' ' '{print "0000:"$1}'`
|
|
||||||
mlx_core_driver="mlx4_core"
|
|
||||||
mlx_ib_driver="mlx4_ib"
|
|
||||||
mlx_en_driver="mlx4_en"
|
|
||||||
|
|
||||||
if [ -z "$nvmf_nic_bdfs" ]; then
|
|
||||||
exit 0
|
|
||||||
fi
|
|
||||||
|
|
||||||
# for nvmf target loopback test, suppose we only have one type of card.
|
|
||||||
for nvmf_nic_bdf in $nvmf_nic_bdfs
|
|
||||||
do
|
|
||||||
result=`find /sys -name $nvmf_nic_bdf | grep driver | awk -F / '{ print $6 }'`
|
|
||||||
if [ "$result" == "mlx5_core" ]; then
|
|
||||||
mlx_core_driver="mlx5_core"
|
|
||||||
mlx_ib_driver="mlx5_ib"
|
|
||||||
mlx_en_driver=""
|
|
||||||
fi
|
|
||||||
break;
|
|
||||||
done
|
|
||||||
|
|
||||||
# Uninstall/install driver to make a clean test environment
|
|
||||||
if lsmod | grep -q $mlx_ib_driver; then
|
|
||||||
rmmod $mlx_ib_driver
|
|
||||||
fi
|
|
||||||
|
|
||||||
if [ -n "$mlx_en_driver" ]; then
|
|
||||||
if lsmod | grep -q $mlx_en_driver; then
|
|
||||||
rmmod $mlx_en_driver
|
|
||||||
fi
|
|
||||||
fi
|
|
||||||
|
|
||||||
if lsmod | grep -q $mlx_core_driver; then
|
|
||||||
rmmod $mlx_core_driver
|
|
||||||
fi
|
|
||||||
|
|
||||||
modprobe $mlx_core_driver
|
|
||||||
modprobe $mlx_ib_driver
|
|
||||||
if [ -n "$mlx_en_driver" ]; then
|
|
||||||
modprobe $mlx_en_driver
|
|
||||||
fi
|
|
||||||
|
|
||||||
trap - SIGINT SIGTERM EXIT
|
|
||||||
}
|
|
||||||
|
|
||||||
function detect_rdma_nics()
|
|
||||||
{
|
|
||||||
detect_mellanox_nics
|
|
||||||
}
|
|
||||||
|
|
||||||
function allocate_nic_ips()
|
|
||||||
{
|
|
||||||
LEAST_ADDR=$NVMF_IP_LEAST_ADDR
|
|
||||||
for bdf in $1; do
|
|
||||||
dir=`find /sys -name $bdf | grep "/sys/devices"`
|
|
||||||
if [ -e $dir ]; then
|
|
||||||
if [ -e $dir"/net" ]; then
|
|
||||||
nic_name=`ls $dir"/net"`
|
|
||||||
echo $nic_name
|
|
||||||
ifconfig $nic_name $NVMF_IP_PREFIX$LEAST_ADDR netmask 255.255.255.0 up
|
|
||||||
LEAST_ADDR=$[$LEAST_ADDR + 1]
|
|
||||||
fi
|
|
||||||
fi
|
|
||||||
done
|
|
||||||
# check whether the IP is configured
|
|
||||||
result=`ifconfig | grep $NVMF_IP_PREFIX`
|
|
||||||
if [ -z "$result" ]; then
|
|
||||||
echo "no NIC for nvmf test"
|
|
||||||
exit 0
|
|
||||||
fi
|
|
||||||
}
|
|
||||||
|
|
||||||
function nvmfcleanup() {
|
|
||||||
rmmod nvme-rdma
|
|
||||||
}
|
|
||||||
|
|
||||||
load_ib_rdma_modules
|
|
||||||
detect_rdma_nics
|
|
||||||
allocate_nic_ips $nvmf_nic_bdfs
|
|
||||||
|
|
||||||
timing_enter fio
|
timing_enter fio
|
||||||
|
|
||||||
|
Loading…