test/vhost: live migration test plan

Change-Id: I25f62d221c251a2ce455bfca7f686bb5817aa7d6
Signed-off-by: Karol Latecki <karol.latecki@intel.com>
Reviewed-on: https://review.gerrithub.io/394199
Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com>
Reviewed-by: Jim Harris <james.r.harris@intel.com>
Reviewed-by: Daniel Verkamp <daniel.verkamp@intel.com>
Tested-by: SPDK Automated Test System <sys_sgsw@intel.com>
This commit is contained in:
Karol Latecki 2018-01-10 12:33:26 +01:00 committed by Daniel Verkamp
parent b1a8455ac8
commit 0ff878d02e

View File

@ -129,6 +129,108 @@ All tests are run in virtio-user mode. Tests 2-3, 5-9 are additionally run in vi
3. Check if fio test ends with success.
4. Repeat steps 1-3 on host for malloc with 4096 block size and 512 block size.
### Live migration
Live migration feature allows to move running virtual machines between SPDK vhost
instances.
Following tests include scenarios with SPDK vhost instances running on both the same
physical server and between remote servers.
Additional configuration of utilities like SSHFS share, NIC IP address adjustment,
etc., might be necessary.
#### Test case 1 - single vhost migration
- Start SPDK Vhost application.
- Construct a single Malloc bdev.
- Construct two SCSI controllers and add previously created Malloc bdev to it.
- Start first VM (VM_1) and connect to Vhost_1 controller.
Verify if attached disk is visible in the system.
- Start second VM (VM_2) but with "-incoming" option enabled, connect to.
Connect to Vhost_2 controller. Use the same VM image as VM_1.
- On VM_1 start FIO write job with verification enabled to connected Malloc bdev.
- Start VM migration from VM_1 to VM_2 while FIO is still running on VM_1.
- Once migration is complete check the result using Qemu monitor. Migration info
on VM_1 should return "Migration status: completed".
- VM_2 should be up and running after migration. Via SSH log in and check FIO
job result - exit code should be 0 and there should be no data verification errors.
- Cleanup:
- Shutdown both VMs.
- Gracefully shutdown Vhost instance.
#### Test case 2 - single server migration
- Detect RDMA NICs; At least 1 RDMA NIC is needed to run the test.
If there is no physical NIC available then emulated Soft Roce NIC will
be used instead.
- Create /tmp/share directory and put a test VM image in there.
- Start SPDK NVMeOF Target application.
- Construct a single NVMe bdev from available bound NVMe drives.
- Create NVMeoF subsystem with NVMe bdev as single namespace.
- Start first SDPK Vhost application instance (later referred to as "Vhost_1").
- Use different shared memory ID and CPU mask than NVMeOF Target.
- Construct a NVMe bdev by connecting to NVMeOF Target
(using trtype: rdma).
- Construct a single SCSI controller and add NVMe bdev to it.
- Start first VM (VM_1) and connect to Vhost_1 controller. Verify if attached disk
is visible in the system.
- Start second SDPK Vhost application instance (later referred to as "Vhost_2").
- Use different shared memory ID and CPU mask than previous SPDK instances.
- Construct a NVMe bdev by connecting to NVMeOF Target. Connect to the same
subsystem as Vhost_1, multiconnection is allowed.
- Construct a single SCSI controller and add NVMe bdev to it.
- Start second VM (VM_2) but with "-incoming" option enabled.
- Check states of both VMs using Qemu monitor utility.
VM_1 should be in running state.
VM_2 should be in paused (inmigrate) state.
- Run FIO I/O traffic with verification enabled on to attached NVME on VM_1.
- While FIO is running issue a command for VM_1 to migrate.
- When the migrate call returns check the states of VMs again.
VM_1 should be in paused (postmigrate) state. "info migrate" should report
"Migration status: completed".
VM_2 should be in running state.
- Verify that FIO task completed successfully on VM_2 after migrating.
There should be no I/O failures, no verification failures, etc.
- Cleanup:
- Shutdown both VMs.
- Gracefully shutdown Vhost instances and NVMEoF Target instance.
- Remove /tmp/share directory and it's contents.
- Clean RDMA NIC / Soft RoCE configuration.
#### Test case 3 - remote server migration
- Detect RDMA NICs on physical hosts. At least 1 RDMA NIC per host is needed
to run the test.
- On Host 1 create /tmp/share directory and put a test VM image in there.
- On Host 2 create /tmp/share directory. Using SSHFS mount /tmp/share from Host 1
so that the same VM image can be used on both hosts.
- Start SPDK NVMeOF Target application on Host 1.
- Construct a single NVMe bdev from available bound NVMe drives.
- Create NVMeoF subsystem with NVMe bdev as single namespace.
- Start first SDPK Vhost application instance on Host 1(later referred to as "Vhost_1").
- Use different shared memory ID and CPU mask than NVMeOF Target.
- Construct a NVMe bdev by connecting to NVMeOF Target
(using trtype: rdma).
- Construct a single SCSI controller and add NVMe bdev to it.
- Start first VM (VM_1) and connect to Vhost_1 controller. Verify if attached disk
is visible in the system.
- Start second SDPK Vhost application instance on Host 2(later referred to as "Vhost_2").
- Construct a NVMe bdev by connecting to NVMeOF Target. Connect to the same
subsystem as Vhost_1, multiconnection is allowed.
- Construct a single SCSI controller and add NVMe bdev to it.
- Start second VM (VM_2) but with "-incoming" option enabled.
- Check states of both VMs using Qemu monitor utility.
VM_1 should be in running state.
VM_2 should be in paused (inmigrate) state.
- Run FIO I/O traffic with verification enabled on to attached NVME on VM_1.
- While FIO is running issue a command for VM_1 to migrate.
- When the migrate call returns check the states of VMs again.
VM_1 should be in paused (postmigrate) state. "info migrate" should report
"Migration status: completed".
VM_2 should be in running state.
- Verify that FIO task completed successfully on VM_2 after migrating.
There should be no I/O failures, no verification failures, etc.
- Cleanup:
- Shutdown both VMs.
- Gracefully shutdown Vhost instances and NVMEoF Target instance.
- Remove /tmp/share directory and it's contents.
- Clean RDMA NIC configuration.
### Performance tests