test/vhost: live migration test plan
Change-Id: I25f62d221c251a2ce455bfca7f686bb5817aa7d6 Signed-off-by: Karol Latecki <karol.latecki@intel.com> Reviewed-on: https://review.gerrithub.io/394199 Reviewed-by: Tomasz Zawadzki <tomasz.zawadzki@intel.com> Reviewed-by: Jim Harris <james.r.harris@intel.com> Reviewed-by: Daniel Verkamp <daniel.verkamp@intel.com> Tested-by: SPDK Automated Test System <sys_sgsw@intel.com>
This commit is contained in:
parent
b1a8455ac8
commit
0ff878d02e
@ -129,6 +129,108 @@ All tests are run in virtio-user mode. Tests 2-3, 5-9 are additionally run in vi
|
||||
3. Check if fio test ends with success.
|
||||
4. Repeat steps 1-3 on host for malloc with 4096 block size and 512 block size.
|
||||
|
||||
### Live migration
|
||||
Live migration feature allows to move running virtual machines between SPDK vhost
|
||||
instances.
|
||||
Following tests include scenarios with SPDK vhost instances running on both the same
|
||||
physical server and between remote servers.
|
||||
Additional configuration of utilities like SSHFS share, NIC IP address adjustment,
|
||||
etc., might be necessary.
|
||||
|
||||
#### Test case 1 - single vhost migration
|
||||
- Start SPDK Vhost application.
|
||||
- Construct a single Malloc bdev.
|
||||
- Construct two SCSI controllers and add previously created Malloc bdev to it.
|
||||
- Start first VM (VM_1) and connect to Vhost_1 controller.
|
||||
Verify if attached disk is visible in the system.
|
||||
- Start second VM (VM_2) but with "-incoming" option enabled, connect to.
|
||||
Connect to Vhost_2 controller. Use the same VM image as VM_1.
|
||||
- On VM_1 start FIO write job with verification enabled to connected Malloc bdev.
|
||||
- Start VM migration from VM_1 to VM_2 while FIO is still running on VM_1.
|
||||
- Once migration is complete check the result using Qemu monitor. Migration info
|
||||
on VM_1 should return "Migration status: completed".
|
||||
- VM_2 should be up and running after migration. Via SSH log in and check FIO
|
||||
job result - exit code should be 0 and there should be no data verification errors.
|
||||
- Cleanup:
|
||||
- Shutdown both VMs.
|
||||
- Gracefully shutdown Vhost instance.
|
||||
|
||||
#### Test case 2 - single server migration
|
||||
- Detect RDMA NICs; At least 1 RDMA NIC is needed to run the test.
|
||||
If there is no physical NIC available then emulated Soft Roce NIC will
|
||||
be used instead.
|
||||
- Create /tmp/share directory and put a test VM image in there.
|
||||
- Start SPDK NVMeOF Target application.
|
||||
- Construct a single NVMe bdev from available bound NVMe drives.
|
||||
- Create NVMeoF subsystem with NVMe bdev as single namespace.
|
||||
- Start first SDPK Vhost application instance (later referred to as "Vhost_1").
|
||||
- Use different shared memory ID and CPU mask than NVMeOF Target.
|
||||
- Construct a NVMe bdev by connecting to NVMeOF Target
|
||||
(using trtype: rdma).
|
||||
- Construct a single SCSI controller and add NVMe bdev to it.
|
||||
- Start first VM (VM_1) and connect to Vhost_1 controller. Verify if attached disk
|
||||
is visible in the system.
|
||||
- Start second SDPK Vhost application instance (later referred to as "Vhost_2").
|
||||
- Use different shared memory ID and CPU mask than previous SPDK instances.
|
||||
- Construct a NVMe bdev by connecting to NVMeOF Target. Connect to the same
|
||||
subsystem as Vhost_1, multiconnection is allowed.
|
||||
- Construct a single SCSI controller and add NVMe bdev to it.
|
||||
- Start second VM (VM_2) but with "-incoming" option enabled.
|
||||
- Check states of both VMs using Qemu monitor utility.
|
||||
VM_1 should be in running state.
|
||||
VM_2 should be in paused (inmigrate) state.
|
||||
- Run FIO I/O traffic with verification enabled on to attached NVME on VM_1.
|
||||
- While FIO is running issue a command for VM_1 to migrate.
|
||||
- When the migrate call returns check the states of VMs again.
|
||||
VM_1 should be in paused (postmigrate) state. "info migrate" should report
|
||||
"Migration status: completed".
|
||||
VM_2 should be in running state.
|
||||
- Verify that FIO task completed successfully on VM_2 after migrating.
|
||||
There should be no I/O failures, no verification failures, etc.
|
||||
- Cleanup:
|
||||
- Shutdown both VMs.
|
||||
- Gracefully shutdown Vhost instances and NVMEoF Target instance.
|
||||
- Remove /tmp/share directory and it's contents.
|
||||
- Clean RDMA NIC / Soft RoCE configuration.
|
||||
|
||||
#### Test case 3 - remote server migration
|
||||
- Detect RDMA NICs on physical hosts. At least 1 RDMA NIC per host is needed
|
||||
to run the test.
|
||||
- On Host 1 create /tmp/share directory and put a test VM image in there.
|
||||
- On Host 2 create /tmp/share directory. Using SSHFS mount /tmp/share from Host 1
|
||||
so that the same VM image can be used on both hosts.
|
||||
- Start SPDK NVMeOF Target application on Host 1.
|
||||
- Construct a single NVMe bdev from available bound NVMe drives.
|
||||
- Create NVMeoF subsystem with NVMe bdev as single namespace.
|
||||
- Start first SDPK Vhost application instance on Host 1(later referred to as "Vhost_1").
|
||||
- Use different shared memory ID and CPU mask than NVMeOF Target.
|
||||
- Construct a NVMe bdev by connecting to NVMeOF Target
|
||||
(using trtype: rdma).
|
||||
- Construct a single SCSI controller and add NVMe bdev to it.
|
||||
- Start first VM (VM_1) and connect to Vhost_1 controller. Verify if attached disk
|
||||
is visible in the system.
|
||||
- Start second SDPK Vhost application instance on Host 2(later referred to as "Vhost_2").
|
||||
- Construct a NVMe bdev by connecting to NVMeOF Target. Connect to the same
|
||||
subsystem as Vhost_1, multiconnection is allowed.
|
||||
- Construct a single SCSI controller and add NVMe bdev to it.
|
||||
- Start second VM (VM_2) but with "-incoming" option enabled.
|
||||
- Check states of both VMs using Qemu monitor utility.
|
||||
VM_1 should be in running state.
|
||||
VM_2 should be in paused (inmigrate) state.
|
||||
- Run FIO I/O traffic with verification enabled on to attached NVME on VM_1.
|
||||
- While FIO is running issue a command for VM_1 to migrate.
|
||||
- When the migrate call returns check the states of VMs again.
|
||||
VM_1 should be in paused (postmigrate) state. "info migrate" should report
|
||||
"Migration status: completed".
|
||||
VM_2 should be in running state.
|
||||
- Verify that FIO task completed successfully on VM_2 after migrating.
|
||||
There should be no I/O failures, no verification failures, etc.
|
||||
- Cleanup:
|
||||
- Shutdown both VMs.
|
||||
- Gracefully shutdown Vhost instances and NVMEoF Target instance.
|
||||
- Remove /tmp/share directory and it's contents.
|
||||
- Clean RDMA NIC configuration.
|
||||
|
||||
### Performance tests
|
||||
Tests verifying the performance and efficiency of the module.
|
||||
|
||||
|