Spdk/test/nvmf/target/nvme_cli.sh

74 lines
2.2 KiB
Bash
Raw Normal View History

#!/usr/bin/env bash
testdir=$(readlink -f $(dirname $0))
rootdir=$(readlink -f $testdir/../../..)
source $rootdir/test/common/autotest_common.sh
source $rootdir/test/nvmf/common.sh
if [ -z "${DEPENDENCY_DIR}" ]; then
echo DEPENDENCY_DIR not defined!
exit 1
fi
spdk_nvme_cli="${DEPENDENCY_DIR}/nvme-cli"
MALLOC_BDEV_SIZE=64
MALLOC_BLOCK_SIZE=512
rpc_py="$rootdir/scripts/rpc.py"
nvmftestinit
nvmfappstart "-m 0xF"
$rpc_py nvmf_create_transport $NVMF_TRANSPORT_OPTS -u 8192
$rpc_py bdev_malloc_create $MALLOC_BDEV_SIZE $MALLOC_BLOCK_SIZE -b Malloc0
$rpc_py bdev_malloc_create $MALLOC_BDEV_SIZE $MALLOC_BLOCK_SIZE -b Malloc1
$rpc_py nvmf_create_subsystem nqn.2016-06.io.spdk:cnode1 -a -s $NVMF_SERIAL -d SPDK_Controller1
$rpc_py nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode1 Malloc0
$rpc_py nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode1 Malloc1
$rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode1 -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s $NVMF_PORT
nvme connect -t $TEST_TRANSPORT -n "nqn.2016-06.io.spdk:cnode1" -a "$NVMF_FIRST_TARGET_IP" -s "$NVMF_PORT"
waitforserial $NVMF_SERIAL 2
nvme list
for ctrl in /dev/nvme?; do
nvme id-ctrl $ctrl
nvme smart-log $ctrl
nvme_model=$(nvme id-ctrl $ctrl | grep -w mn | sed 's/^.*: //' | sed 's/ *$//')
if [ "$nvme_model" != "SPDK_Controller1" ]; then
echo "Wrong model number for controller" $nvme_model
exit 1
fi
done
for ns in /dev/nvme?n*; do
nvme id-ns $ns
done
nvme disconnect -n "nqn.2016-06.io.spdk:cnode1"
if [ -d $spdk_nvme_cli ]; then
# Test spdk/nvme-cli NVMe-oF commands: discover, connect and disconnect
cd $spdk_nvme_cli
sed -i 's/shm_id=.*/shm_id=-1/g' spdk.conf
./nvme discover -t $TEST_TRANSPORT -a $NVMF_FIRST_TARGET_IP -s "$NVMF_PORT"
nvme_num_before_connection=$(nvme list |grep "/dev/nvme"|awk '{print $1}'|wc -l)
./nvme connect -t $TEST_TRANSPORT -n "nqn.2016-06.io.spdk:cnode1" -a "$NVMF_FIRST_TARGET_IP" -s "$NVMF_PORT"
sleep 1
nvme_num=$(nvme list |grep "/dev/nvme"|awk '{print $1}'|wc -l)
./nvme disconnect -n "nqn.2016-06.io.spdk:cnode1"
if [ $nvme_num -le $nvme_num_before_connection ]; then
echo "spdk/nvme-cli connect target devices failed"
exit 1
fi
fi
$rpc_py nvmf_delete_subsystem nqn.2016-06.io.spdk:cnode1
trap - SIGINT SIGTERM EXIT
nvmftestfini