#!/usr/bin/env bash
testdir=$(readlink -f $(dirname $0))
rootdir=$(readlink -f $testdir/../../..)
source $rootdir/test/common/autotest_common.sh
source $rootdir/scripts/common.sh
source $rootdir/test/nvmf/common.sh
rpc_py="$rootdir/scripts/rpc.py"
set -e
# pass the parameter 'iso' to this script when running it in isolation to trigger rdma device initialization.
# e.g. sudo ./fio.sh iso
nvmftestinit $1
RDMA_IP_LIST=$(get_available_rdma_ips)
NVMF_FIRST_TARGET_IP=$(echo "$RDMA_IP_LIST" | head -n 1)
if [ -z $NVMF_FIRST_TARGET_IP ]; then
echo "no NIC for nvmf test"
exit 0
fi
if [ ! -d /usr/src/fio ]; then
echo "FIO not available"
exit 0
fi
timing_enter fio
timing_enter start_nvmf_tgt
$NVMF_APP -m 0xF &
nvmfpid=$!
trap "process_shm --id $NVMF_APP_SHM_ID; killprocess $nvmfpid; nvmftestfini $1; exit 1" SIGINT SIGTERM EXIT
waitforlisten $nvmfpid
$rpc_py nvmf_create_transport -t RDMA -u 8192 -p 4
timing_exit start_nvmf_tgt
$rpc_py construct_malloc_bdev 64 512 -b Malloc1
$rpc_py nvmf_subsystem_create nqn.2016-06.io.spdk:cnode1 -a -s SPDK00000000000001
$rpc_py nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode1 Malloc1
$rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode1 -t rdma -a $NVMF_FIRST_TARGET_IP -s 4420
PLUGIN_DIR=$rootdir/examples/nvme/fio_plugin
# Test fio_plugin as host with malloc backend
LD_PRELOAD=$PLUGIN_DIR/fio_plugin /usr/src/fio/fio $PLUGIN_DIR/example_config.fio --filename="trtype=RDMA adrfam=IPv4 \
traddr=$NVMF_FIRST_TARGET_IP trsvcid=4420 ns=1"
# second test mocking multiple SGL elements
LD_PRELOAD=$PLUGIN_DIR/fio_plugin /usr/src/fio/fio $PLUGIN_DIR/mock_sgl_config.fio --filename="trtype=RDMA adrfam=IPv4 \
traddr=$NVMF_FIRST_TARGET_IP trsvcid=4420 ns=1"
$rpc_py delete_nvmf_subsystem nqn.2016-06.io.spdk:cnode1
if [ $RUN_NIGHTLY -eq 1 ]; then
# Test fio_plugin as host with nvme lvol backend
bdfs=$(iter_pci_class_code 01 08 02)
$rpc_py construct_nvme_bdev -b Nvme0 -t PCIe -a $(echo $bdfs | awk '{ print $1 }') -i $NVMF_FIRST_TARGET_IP
$rpc_py construct_lvol_store Nvme0n1 lvs_0
get_lvs_free_mb lvs_0
$rpc_py construct_lvol_bdev -l lvs_0 lbd_0 $free_mb
$rpc_py nvmf_subsystem_create nqn.2016-06.io.spdk:cnode2 -a -s SPDK00000000000001
$rpc_py nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode2 lvs_0/lbd_0
$rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode2 -t rdma -a $NVMF_FIRST_TARGET_IP -s 4420
LD_PRELOAD=$PLUGIN_DIR/fio_plugin /usr/src/fio/fio $PLUGIN_DIR/example_config.fio --filename="trtype=RDMA adrfam=IPv4 \
traddr=$NVMF_FIRST_TARGET_IP trsvcid=4420 ns=1"
$rpc_py delete_nvmf_subsystem nqn.2016-06.io.spdk:cnode2
# Test fio_plugin as host with nvme lvol nested backend
$rpc_py construct_lvol_store lvs_0/lbd_0 lvs_n_0
get_lvs_free_mb lvs_n_0
$rpc_py construct_lvol_bdev -l lvs_n_0 lbd_nest_0 $free_mb
$rpc_py nvmf_subsystem_create nqn.2016-06.io.spdk:cnode3 -a -s SPDK00000000000001
$rpc_py nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode3 lbd_nest_0/lvs_n_0
$rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode3 -t rdma -a $NVMF_FIRST_TARGET_IP -s 4420
LD_PRELOAD=$PLUGIN_DIR/fio_plugin /usr/src/fio/fio $PLUGIN_DIR/example_config.fio --filename="trtype=RDMA adrfam=IPv4 \
traddr=$NVMF_FIRST_TARGET_IP trsvcid=4420 ns=1"
$rpc_py delete_nvmf_subsystem nqn.2016-06.io.spdk:cnode3
sync
# Delete lvol_bdev and destroy lvol_store.
$rpc_py destroy_lvol_bdev lbd_nest_0/lvs_n_0
$rpc_py destroy_lvol_store -l lvs_n_0
$rpc_py destroy_lvol_bdev lvs_0/lbd_0
$rpc_py destroy_lvol_store -l lvs_0
$rpc_py delete_nvme_controller Nvme0
fi
trap - SIGINT SIGTERM EXIT
rm -f ./local-test-0-verify.state
killprocess $nvmfpid
nvmftestfini $1
timing_exit fio