2019-10-17 17:14:11 +00:00
|
|
|
#!/usr/bin/env bash
|
2022-11-02 15:49:40 +00:00
|
|
|
# SPDX-License-Identifier: BSD-3-Clause
|
|
|
|
# Copyright (C) 2019 Intel Corporation
|
|
|
|
# All rights reserved.
|
|
|
|
#
|
2019-10-17 17:14:11 +00:00
|
|
|
testdir=$(readlink -f $(dirname $0))
|
|
|
|
rootdir=$(readlink -f $testdir/../../..)
|
|
|
|
source $rootdir/test/common/autotest_common.sh
|
|
|
|
source $rootdir/test/nvmf/common.sh
|
|
|
|
|
|
|
|
PLUGIN_DIR=$rootdir/examples/nvme/fio_plugin
|
|
|
|
|
|
|
|
MALLOC_BDEV_SIZE=64
|
|
|
|
MALLOC_BLOCK_SIZE=512
|
|
|
|
|
2020-05-07 11:27:06 +00:00
|
|
|
function disconnect_init() {
|
2020-04-28 15:08:33 +00:00
|
|
|
nvmfappstart -m 0xF0
|
2019-10-17 17:14:11 +00:00
|
|
|
|
|
|
|
$rpc_py bdev_malloc_create $MALLOC_BDEV_SIZE $MALLOC_BLOCK_SIZE -b Malloc0
|
|
|
|
|
|
|
|
$rpc_py nvmf_create_transport $NVMF_TRANSPORT_OPTS
|
2021-04-29 14:37:55 +00:00
|
|
|
$rpc_py nvmf_create_subsystem nqn.2016-06.io.spdk:cnode1 -a -s SPDK00000000000001
|
2019-10-17 17:14:11 +00:00
|
|
|
|
|
|
|
$rpc_py nvmf_subsystem_add_ns nqn.2016-06.io.spdk:cnode1 Malloc0
|
2019-10-23 22:58:47 +00:00
|
|
|
$rpc_py nvmf_subsystem_add_listener nqn.2016-06.io.spdk:cnode1 -t $TEST_TRANSPORT -a $1 -s $NVMF_PORT
|
2022-02-10 11:09:12 +00:00
|
|
|
$rpc_py nvmf_subsystem_add_listener discovery -t $TEST_TRANSPORT -a $1 -s $NVMF_PORT
|
2019-10-17 17:14:11 +00:00
|
|
|
}
|
|
|
|
|
2019-11-13 23:20:09 +00:00
|
|
|
# Test to make sure we don't segfault or access null pointers when we try to connect to
|
|
|
|
# a discovery controller that doesn't exist yet.
|
2020-05-07 11:27:06 +00:00
|
|
|
function nvmf_target_disconnect_tc1() {
|
2019-12-04 22:52:05 +00:00
|
|
|
set +e
|
2020-05-11 22:02:01 +00:00
|
|
|
$SPDK_EXAMPLE_DIR/reconnect -q 32 -o 4096 -w randrw -M 50 -t 10 -c 0xF \
|
2020-05-07 11:27:06 +00:00
|
|
|
-r "trtype:$TEST_TRANSPORT adrfam:IPv4 traddr:$NVMF_FIRST_TARGET_IP trsvcid:$NVMF_PORT"
|
2019-12-04 22:52:05 +00:00
|
|
|
# If the program crashes, the high bit of $? will be set so we will get a value in the hundreds.
|
|
|
|
# But if the reconnect code detects errors and exits normally it will return 1.
|
|
|
|
if [ $? != 1 ]; then
|
|
|
|
set -e
|
|
|
|
exit 1
|
|
|
|
fi
|
2019-11-13 23:20:09 +00:00
|
|
|
set -e
|
2019-12-04 22:52:05 +00:00
|
|
|
}
|
2019-10-17 17:14:11 +00:00
|
|
|
|
2020-05-07 11:27:06 +00:00
|
|
|
function nvmf_target_disconnect_tc2() {
|
2019-12-04 22:52:05 +00:00
|
|
|
disconnect_init $NVMF_FIRST_TARGET_IP
|
2019-10-17 17:14:11 +00:00
|
|
|
|
2019-12-04 22:52:05 +00:00
|
|
|
# If perf doesn't shut down, this test will time out.
|
2020-05-11 22:02:01 +00:00
|
|
|
$SPDK_EXAMPLE_DIR/reconnect -q 32 -o 4096 -w randrw -M 50 -t 10 -c 0xF \
|
2020-05-07 11:27:06 +00:00
|
|
|
-r "trtype:$TEST_TRANSPORT adrfam:IPv4 traddr:$NVMF_FIRST_TARGET_IP trsvcid:$NVMF_PORT" &
|
2019-12-04 22:52:05 +00:00
|
|
|
reconnectpid=$!
|
2019-10-17 17:14:11 +00:00
|
|
|
|
2019-12-04 22:52:05 +00:00
|
|
|
sleep 2
|
|
|
|
kill -9 $nvmfpid
|
2019-10-17 17:14:11 +00:00
|
|
|
|
2019-12-04 22:52:05 +00:00
|
|
|
sleep 2
|
|
|
|
disconnect_init $NVMF_FIRST_TARGET_IP
|
2019-10-17 17:14:11 +00:00
|
|
|
|
2019-12-04 22:52:05 +00:00
|
|
|
wait $reconnectpid
|
|
|
|
sync
|
|
|
|
}
|
2019-10-23 22:58:47 +00:00
|
|
|
|
2020-05-07 11:27:06 +00:00
|
|
|
function nvmf_target_disconnect_tc3() {
|
2020-05-11 22:02:01 +00:00
|
|
|
$SPDK_EXAMPLE_DIR/reconnect -q 32 -o 4096 -w randrw -M 50 -t 10 -c 0xF \
|
2020-05-07 11:27:06 +00:00
|
|
|
-r "trtype:$TEST_TRANSPORT adrfam:IPv4 traddr:$NVMF_FIRST_TARGET_IP trsvcid:$NVMF_PORT alt_traddr:$NVMF_SECOND_TARGET_IP" &
|
2019-10-23 22:58:47 +00:00
|
|
|
reconnectpid=$!
|
|
|
|
|
|
|
|
sleep 2
|
|
|
|
kill -9 $nvmfpid
|
|
|
|
|
|
|
|
sleep 2
|
|
|
|
disconnect_init $NVMF_SECOND_TARGET_IP
|
|
|
|
|
|
|
|
wait $reconnectpid
|
|
|
|
sync
|
2019-12-04 22:52:05 +00:00
|
|
|
}
|
2019-10-23 22:58:47 +00:00
|
|
|
|
2019-12-04 22:52:05 +00:00
|
|
|
nvmftestinit
|
2020-07-30 09:00:35 +00:00
|
|
|
run_test "nvmf_target_disconnect_tc1" nvmf_target_disconnect_tc1
|
|
|
|
run_test "nvmf_target_disconnect_tc2" nvmf_target_disconnect_tc2
|
|
|
|
if [ -n "$NVMF_SECOND_TARGET_IP" ]; then
|
|
|
|
run_test "nvmf_target_disconnect_tc3" nvmf_target_disconnect_tc3
|
2019-12-04 22:52:05 +00:00
|
|
|
fi
|
|
|
|
|
2019-10-17 17:14:11 +00:00
|
|
|
trap - SIGINT SIGTERM EXIT
|
|
|
|
nvmftestfini
|